EconPapers    
Economics at your fingertips  
 

Optimal Design of Corona Ring for 132 kV Insulator at High Voltage Transmission Lines Based on Optimisation Techniques

Kalaiselvi Aramugam, Hazlee Azil Illias (), Yern Chee Ching, Mohd Syukri Ali and Mohamad Zul Hilmey Makmud ()
Additional contact information
Kalaiselvi Aramugam: Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
Hazlee Azil Illias: Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
Yern Chee Ching: Department of Chemical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
Mohd Syukri Ali: Higher Institution Centre of Excellence (HICoE), UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D, University of Malaya, Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
Mohamad Zul Hilmey Makmud: Faculty of Science and Natural Resources, Universiti Malaysia Sabah, Kota Kinabalu 88400, Sabah, Malaysia

Energies, 2023, vol. 16, issue 2, 1-18

Abstract: The installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to reduce the electric field magnitude on an insulator string is a challenging task. Therefore, in this work, a method to achieve the optimum design of a corona ring for 132 kV composite non-ceramic insulator string was proposed using two optimisation methods: the Imperialist Competitive Algorithm (ICA) and Grey Wolf Optimisation (GWO). A composite non-ceramic insulator string geometry with and without a corona ring was modelled in finite element analysis and used to obtain the electric field distribution in the model geometry. The electric field distribution was evaluated using a variation in the corona ring’s dimensions, i.e., the ring diameter, the ring tube diameter and the vertical position of the ring along the insulator string. From the results achieved, a comparison of the minimum electric field magnitude along the insulator string with a corona ring design shows that the minimum electric field magnitude is found to be lower using optimisation techniques compared to without using optimisation techniques by between 3.724% and 3.827%. Hence, this indicates the capability and effectiveness of the proposed methods in achieving the optimum design of a corona ring on an insulator string.

Keywords: insulator strings; optimisation techniques; high voltage engineering; transmission lines; corona ring; finite element analysis (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/2/778/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/2/778/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:2:p:778-:d:1030233

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:2:p:778-:d:1030233