Internal Flow Field and Loss Analysis of a Magnetic Drive Pump’s Cooling Circuit
Zhenfa Xu (),
Fanyu Kong,
Kun Zhang,
Yinfeng Wang,
Jiaqiong Wang and
Ning Qiu
Additional contact information
Zhenfa Xu: School of Mechanical Engineering, Anhui Polytechnic University, Wuhu 241000, China
Fanyu Kong: Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
Kun Zhang: Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
Yinfeng Wang: School of Mechanical Engineering, Anhui Polytechnic University, Wuhu 241000, China
Jiaqiong Wang: Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
Ning Qiu: Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
Energies, 2023, vol. 16, issue 2, 1-18
Abstract:
The cooling circuit is an important component of the magnetic drive pump because it prevents demagnetization of the permanent magnet and damage to the containment shell owing to a high temperature increase. In this paper, the flow field and losses of the cooling circuit of the magnetic pump are discussed and experimentally verified based on numerical simulation methods. Five different lengths of magnetic couplings were designed, and the flow field distribution, cooling flow rate, and loss variation laws of the cooling circuit were analyzed. The results show that the pump flow rate and magnetic coupling length have a minimal effect on the velocity distribution in the cooling circuit. When the magnet length increases from 30 mm to 55 mm, the temperature rise of the cooling circuit and the pressure drop at the gap increase by 23.1% and 25.3%, respectively. When the length of the magnetic coupling remains constant, the cooling flow rate of the cooling circuit falls with an increasing pump flow rate, and it reduces by 8.4% when the pump flow rate increases from 0.7 Q to 1.3 Q. The water friction loss and eddy current loss of the cooling circuit increase with an increase in the magnetic coupling length, while the cooling flow rate decreases. When the magnet length increases from 30 mm to 55 mm, the eddy current losses in the coupling circuit and the water friction losses in the cooling circuit increase by 45% and 35%, respectively, while the cooling flow rate decreases by 13%.
Keywords: numerical simulation; magnetic drive pump; water friction loss; cooling circuit (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/2/840/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/2/840/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:2:p:840-:d:1032308
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().