Method for Evaluating the Effectiveness of Electrical Circuit Protection with Miniature Fuse-Links
Jarosław Łukasiak,
Michał Wiśnios and
Adam Rosiński ()
Additional contact information
Jarosław Łukasiak: Division of Electronic Systems Exploitations, Institute of Electronic Systems, Faculty of Electronics, Military University of Technology, 2 Gen. S. Kaliski St, 00-908 Warsaw, Poland
Michał Wiśnios: Division of Electronic Systems Exploitations, Institute of Electronic Systems, Faculty of Electronics, Military University of Technology, 2 Gen. S. Kaliski St, 00-908 Warsaw, Poland
Adam Rosiński: Division of Air Transport Engineering and Teleinformatics, Faculty of Transport, Warsaw University of Technology, 75 Koszykowa St, 00-662 Warsaw, Poland
Energies, 2023, vol. 16, issue 2, 1-28
Abstract:
Miniature fuses as an anti-damage subsystem perform the important function of protecting electronic devices and systems against permanent damage that may result in electric shocks, fire risks, etc. Their role becomes particularly important when they are installed in such special systems as electronic security systems (ESS). For this reason, there is a need for practical verification of their protective properties. The article presents the results of destructive tests of the circuit-breaking time of miniature fuse-links considered in terms of their usefulness in the ESS with the use of a passive experimental add-on, developed at the Military University of Technology in Warsaw. The characteristics of the measuring attachment circuit and the measurement methodology used were presented. Based on the obtained measurement points of the obtained time–current characteristics, an attempt was made to develop their mathematical model using numerical methods in the field of non-linear regression, using the least squares optimization method (Levenberg–Marquardt algorithm). An exemplary classification of miniature fuse-links has been proposed due to their protective properties of circuits in the context of their use in electronic security systems. The considerations were summarized with an economic analysis of the tested fuse links. The conclusions include proposals for changes to the provisions of the European standard PN-EN 50131-1:2009 “Alarm systems: Intrusion and hold-up systems Part 1: System requirements” and Polish Defence Standard NO-04-A004-8 2016 “Military facilities. Alarm systems. Part 8: Operation”.
Keywords: cartridge fuses; fuse-links; miniature fuses; electronic security systems; reliability; operation process; destructive testing; non-linear regression; Levenberg–Marquardt optimization; modelling (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/2/960/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/2/960/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:2:p:960-:d:1036172
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI