EconPapers    
Economics at your fingertips  
 

CFD Simulation Study on the Air Side of a CO 2 Evaporator in a Motor Train Unit Air Conditioning System

Hongjiang Cui, Xiaoke Su, Ying Guan () and Jiyou Fei
Additional contact information
Hongjiang Cui: School of Locomotive and Rolling Stock Engineering, Dalian Jiaotong University, Dalian 116028, China
Xiaoke Su: School of Locomotive and Rolling Stock Engineering, Dalian Jiaotong University, Dalian 116028, China
Ying Guan: School of Locomotive and Rolling Stock Engineering, Dalian Jiaotong University, Dalian 116028, China
Jiyou Fei: School of Locomotive and Rolling Stock Engineering, Dalian Jiaotong University, Dalian 116028, China

Energies, 2023, vol. 16, issue 3, 1-14

Abstract: At present, China’s high-speed rail is in a period of rapid development. Most of the refrigerants used in Chinese motor train units at this stage are still R134a and R407c, which have an impact on the environment. In response to the environmental protection concept of green travel, it is of great significance to study the air conditioning system of motor train units using CO 2 refrigerant. Using CFD simulation analysis technology, the heat transfer performance of the air side of the CO 2 finned tube evaporator used in the air conditioning system of the motor train unit is studied. We select the air outlet temperature, pressure drop, heat transfer factor, and resistance factor as the objective function, in addition, monitoring points are set up in the air flow channel to monitor the turbulent flow field and pipe wall pressure. Our research shows that the cooling capacity of the CO 2 evaporator can reach up to 29.76 kW, which can meet the heat exchange required in the air conditioning system of the motor train unit. In order to obtain a better structure and the conditions of the heat transfer effect, structural optimization was conducted. The simulation results demonstrate several trends: (i) With the augment of the air inlet velocity, the cooling capacity of the evaporator increases and the heat exchange effect improves; when the air inlet v e > 2.2 m/s, the effect of continuing to augment v e on heat exchange is weak. (ii) Following appropriate reduction of the diameter of the heat exchange tube, the wind resistance is reduced and the cooling capacity of the evaporator is improved. (iii) With the enlargement of the fin spacing, the turbulent motion in the flow channel can be fully developed, there is a peak in the change in the heat exchange tube area optimization factor, and the optimal fin spacing is between 1.6 mm and 1.7 mm; at this time, the average turbulent kinetic energy of the air side is larger and the turbulent dissipation rate is smaller. These results provide a reference for the practical application of CO 2 refrigerant in the motor train unit.

Keywords: finned-tube evaporator; refrigerant CO 2; CFD simulation; heat transfer; resistance coefficient; heatsink transfer factor (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/3/1037/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/3/1037/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:3:p:1037-:d:1038880

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:3:p:1037-:d:1038880