Comparative Study on Boiling Heat Transfer Characteristics and Performance of Low-Temperature Heating System of R744 and Its Azeotropic Refrigerant
Dahan Sun,
Xin Zhang,
Zhongyan Liu () and
Hao Zhang
Additional contact information
Dahan Sun: School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Xin Zhang: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Zhongyan Liu: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Hao Zhang: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Energies, 2023, vol. 16, issue 3, 1-27
Abstract:
R744 is the most competitive and ideal natural refrigerant when flammability and toxicity are strictly limited. However, there are still some problems when it is applied to a heating system. For example, the discharge pressure of the system exceeds 10 MPa, it increases the cost of the system, and the cycle efficiency is also low. To solve these problems, this paper proposes to replace R744 by mixing R744 and ethane at a ratio of (77.6/22.4) to form an azeotropic refrigerant. At present, there is little research on R744 azeotropic refrigerant. Therefore, this paper first establishes the CFD model and compiles the UDF program to focus on flow boiling heat transfer characteristics, and then, it analyzes the performance of R744 and its azeotropic refrigerant in a low-temperature heating system. The results show that the heat transfer coefficient of R744 and its azeotropic refrigerant decreases with an increase in mass flux and increases with an increase in heat flux and saturation temperature; the heat transfer coefficient of azeotropic refrigerant is greater than R744; and there is no dryness under the same conditions. Under a given operating condition, there is a critical point that makes the performance of azeotropic refrigerant better than R744, and this critical point is related to the outlet temperature of a gas cooler, and the system discharge temperature of azeotropic refrigerant is significantly lower than that of R744. In conclusion, azeotropic refrigerant has certain advantages in heat transfer and system performance compared with R744, which will also play an important role in promoting the replacement of refrigerant in the future.
Keywords: R744; azeotropic refrigerant; COP; 2D model; boiling heat transfer; refrigerant replacement (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/3/1313/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/3/1313/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:3:p:1313-:d:1047585
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().