Soft-Switching Full-Bridge DC-DC Converter with Energy Recovery Capacitor Snubber
Marek Pastor,
Milan Lacko (),
Jaroslav Dudrik and
Adrian Marcinek
Additional contact information
Marek Pastor: Department of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letna 9, 042 00 Kosice, Slovakia
Milan Lacko: Department of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letna 9, 042 00 Kosice, Slovakia
Jaroslav Dudrik: Department of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letna 9, 042 00 Kosice, Slovakia
Adrian Marcinek: Department of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letna 9, 042 00 Kosice, Slovakia
Energies, 2023, vol. 16, issue 4, 1-18
Abstract:
This paper describes a high-frequency soft-switching dc-dc converter with a simple energy recovery capacitor snubber on the secondary side. The presented dc-dc full-bridge converter with the energy recovery snubber removes the main drawbacks of the classic Phase Shifted PWM (PS-PWM) dc-dc converter, e.g., the circulating current flowing during the free-wheeling interval and dependency of the soft switching on the load current. The converter utilizes a full-bridge topology with pulse-width modulation and a centre-tapped full-wave controlled rectifier with one active switch. The zero-voltage switching on the primary side is ensured by utilising only the magnetizing current of the high-frequency transformer, and thus is load-independent. The proposed energy recovery snubber is described in detailed time waveforms of the converter and verified by simulation. The control algorithm also removes the circulating current, which is typical for PS-PWM converters. The soft-switching of the secondary side transistor is achieved by a simple capacitor snubber with an energy-recovery circuit connected to the output of the dc-dc converter. The principle of operation is verified by measurements on a 2 kW, 50 kHz laboratory model of the proposed dc-dc converter.
Keywords: dc-dc converter; full-bridge; turn-off snubber; soft-switching (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/4/1591/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/4/1591/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:4:p:1591-:d:1058429
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().