EconPapers    
Economics at your fingertips  
 

Impact of Distributed Generators Penetration Level on the Power Loss and Voltage Profile of Radial Distribution Networks

Sunday Adeleke Salimon, Gafari Abiola Adepoju, Isaiah Gbadegesin Adebayo, Harun Or Rashid Howlader, Samson Oladayo Ayanlade and Oludamilare Bode Adewuyi
Additional contact information
Sunday Adeleke Salimon: Department of Electronic and Electrical Engineering, Ladoke Akintola University of Technology, Ogbomoso 212102, Nigeria
Gafari Abiola Adepoju: Department of Electronic and Electrical Engineering, Ladoke Akintola University of Technology, Ogbomoso 212102, Nigeria
Isaiah Gbadegesin Adebayo: Department of Electronic and Electrical Engineering, Ladoke Akintola University of Technology, Ogbomoso 212102, Nigeria
Harun Or Rashid Howlader: Faculty of Engineering, University of the Ryukyus, 1 Senbaru, Nakagami, Nishihara-cho 903-0213, Okinawa, Japan
Samson Oladayo Ayanlade: Department of Electrical and Electronic Engineering, Lead City University, Ibadan 200255, Nigeria
Oludamilare Bode Adewuyi: Faculty of Engineering, Information and Systems, University of Tsukuba, 1 Chrome-1-1 Tennodai, Tsukuba 305-8577, Ibaraki, Japan

Energies, 2023, vol. 16, issue 4, 1-32

Abstract: The Distributed Generator types have different combinations of real and reactive power characteristics, which can affect the total power loss and the voltage support/control of the radial distribution networks (RDNs) in different ways. This paper investigates the impact of DG’s penetration level (PL) on the power loss and voltage profile of RDNs based on different DG types. The DG types are modeled depending on the real and reactive power they inject. The voltage profiles obtained under various circumstances were fairly compared using the voltage profile index (VPI), which assigns a single value to describe how well the voltages match the ideal voltage. Two novel effective power voltage stability indices were developed to select the most sensitive candidate buses for DG penetration. To assess the influence of the DG PL on the power loss and voltage profile, the sizes of the DG types were gradually raised on these candidate buses by 1% of the total load demand of the RDN. The method was applied to the IEEE 33-bus and 69-bus RDNs. A PL of 45–76% is achieved on the IEEE 33-bus and 48–55% penetration on the IEEE 69-bus without an increase in power loss. The VPI was improved with increasing PL of DG compared to the base case scenario.

Keywords: distributed generation (DG); radial distribution network (RDN); penetration level (PL); voltage profile index (VPI); power loss (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/4/1943/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/4/1943/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:4:p:1943-:d:1069755

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1943-:d:1069755