EconPapers    
Economics at your fingertips  
 

Convenient Procedure for Measuring the Electrical Resistance of Fastening Systems in Urban Railway Tracks

Katarina Vranešić (), Ivo Haladin, Stjepan Lakušić and Krešimir Burnać
Additional contact information
Katarina Vranešić: Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia
Ivo Haladin: Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia
Stjepan Lakušić: Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia
Krešimir Burnać: Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia

Energies, 2023, vol. 16, issue 4, 1-16

Abstract: Electrical resistance is among the characteristics that fastening systems must meet to ensure the proper functioning of signaling systems in railway infrastructure. The EN 13146-5:2012 standard specifies a laboratory testing method for determining the electrical resistance under wet conditions between running rails provided by a fastening system on steel or concrete sleepers. In urban railway tracks, the electrical resistance of fastening systems affects the stray current; however, there is no standardized electrical resistance measuring method. There is also no definition for the minimum value that the electrical resistance of fastening systems must satisfy to prevent stray currents. For this reason, this paper analysis the possibility of using the standard EN 13146-5:2012 for the measurement and analysis of the electrical resistance of fastening systems in urban railway tracks. In this study, the electrical resistance of different fastening systems used in urban railway tracks was measured. Based on the tests results, the modifications needed in the EN 13146-5 standard for it to be suitable for urban railway tracks were identified. The proposed modifications include the use of a DC current source. The test should be performed on a rail sample fastened to the concrete base, and the current circuit should be closed by the reference electrode installed in the base. Spraying water from nozzles is not applicable for this measurement. The test should be performed under dry conditions and at different water levels (water on the top of the concrete base and on the top of the levelling layer). Different water levels were used to simulate the most common conditions in urban railway tracks built as part of the road surface, where the track-drying process is very slow. The test should not be performed when the rails are immersed in water, because the current flows directly from the rail into the water in such case, and the fastening system has no influence on the measured electrical resistance value. In addition to describing the proposed changes, the calculation of the minimum electrical resistance value that fastening systems in urban railway tracks must satisfy is also presented.

Keywords: urban railway track; rail-fastening system; electrical resistance; rail-to-earth resistance; stray current (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/4/1990/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/4/1990/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:4:p:1990-:d:1071561

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1990-:d:1071561