Numerical Investigation with Experimental Validation of Heat and Mass Transfer during Evaporation in the Porous Wick within a Loop Heat Pipe
Suzheng Zheng (),
Binyao Lin,
Chenyang Zhao,
Xue Zhou,
Nanxi Li and
Deping Dong ()
Additional contact information
Suzheng Zheng: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Binyao Lin: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Chenyang Zhao: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Xue Zhou: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Nanxi Li: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Deping Dong: Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Energies, 2023, vol. 16, issue 5, 1-21
Abstract:
The heat transfer performance of the evaporator significantly affects the heat transfer capacity of the loop heat pipe (LHP). The vapor blanket can be formed once the vapor penetrates the wick especially at high heat flux, resulting in an unsaturated state of the wick and deteriorating the evaporator performance. It is crucial to understand the liquid–vapor behavior for enhancing the LHP performance by investigating the fundamental heat and mass transfer in the wick with phase-change. However, previous modeling studies only considered a single-phase flow or complete saturation in the wick, and the capillary effect on the fluid states was rarely taken into account. The present work developed two mathematical models based on the assumptions of saturated and unsaturated wicks. The fluid states were analyzed at the liquid–vapor interface under the consideration of the capillary effect, and a pore-scale evaporation model was applied to study the phase change behavior and interfacial heat and mass transfer. The relative permeability was introduced to describe the two-phase flow in the porous wick, and the capillary force was modeled as a function of the local saturation in the two-phase region. The temperature results calculated by the models were compared with the experimental results, and the assumption that the vapor penetration leads to deterioration of evaporator performance at high heat flux was validated. Vapor blanket thickness can be estimated through the saturation profile, which provides a simple and effective method. It was also found that the capillary number ω was the key factor affecting the thickness of the vapor blanket. The greater the ω , the faster the vapor blanket thickness increases.
Keywords: loop heat pipe; porous wick; phase-change; liquid–vapor interface; two-phase flow; vapor blanket (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/5/2088/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/5/2088/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:5:p:2088-:d:1075325
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().