Adaptive Dynamic Building Envelopes with Solar Power Components: Annual Performance Assessment for Two Pilot Sites
Renos Rotas,
Maria Fotopoulou,
Panagiotis Drosatos,
Dimitrios Rakopoulos () and
Nikos Nikolopoulos
Additional contact information
Renos Rotas: Centre for Research and Technology Hellas, Chemical Process and Energy Resources Institute, 52 Egialias Str., 15125 Athens, Greece
Maria Fotopoulou: Centre for Research and Technology Hellas, Chemical Process and Energy Resources Institute, 52 Egialias Str., 15125 Athens, Greece
Panagiotis Drosatos: Centre for Research and Technology Hellas, Chemical Process and Energy Resources Institute, 52 Egialias Str., 15125 Athens, Greece
Dimitrios Rakopoulos: Centre for Research and Technology Hellas, Chemical Process and Energy Resources Institute, 52 Egialias Str., 15125 Athens, Greece
Nikos Nikolopoulos: Centre for Research and Technology Hellas, Chemical Process and Energy Resources Institute, 52 Egialias Str., 15125 Athens, Greece
Energies, 2023, vol. 16, issue 5, 1-20
Abstract:
Energy consumption reduction and thermal quality improvement constitute two major aspects of building design and/or retrofitting. Following the current energy transition trends, a state-of-the-art solution is the implementation of Adaptive Dynamic Building Envelopes (ADBEs), which are capable of integrating different technologies and components. The purpose of this investigation is to assess the annual performance improvement of two actual building spaces retrofitted with ADBEs, consisting of Building Integrated Photovoltaics (BIPVs), additional thermal insulation, mechanical ventilation system with heat recovery, and solar air heaters (SAHs). Both buildings are pilot sites for the EU Horizon 2020 Plug-n-Harvest project and are located in two rather different climate zones, i.e., Cardiff, Wales, and Grevena, Greece. Moreover, through detailed dynamic modeling with the use of Modelica language, this study attempts to accurately capture all interactions between buildings and all the aforementioned ADBE components. The simulations compared the energy performance and indoor temperature levels in each space before and after the installation of the ADBEs. The results showed that the harvesting of renewable energy through the ADBE system could potentially contribute 60% and 21.8% to the annual electricity and heating load of the space in Cardiff, respectively, and 43.5% to the annual electricity load of the building space in Grevena.
Keywords: adaptive dynamic building envelope; building integrated photovoltaic; building energy performance simulation; energy consumption; solar air heater (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/5/2148/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/5/2148/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:5:p:2148-:d:1077524
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().