Selective Auto-Reclosing of Mixed Circuits Based on Multi-Zone Differential Protection Principle and Distributed Sensing
Kevin Kawal,
Steven Blair (),
Qiteng Hong () and
Panagiotis N. Papadopoulos
Additional contact information
Kevin Kawal: Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1RD, UK
Steven Blair: Synaptec, Glasgow G1 1XW, UK
Qiteng Hong: Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1RD, UK
Panagiotis N. Papadopoulos: Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1RD, UK
Energies, 2023, vol. 16, issue 6, 1-16
Abstract:
Environmental concerns and economic constraints have led to increasing installations of mixed conductor circuits comprising underground cables (UGCs) and overhead transmission lines (OHLs). Faults on the OHL sections of such circuits are usually temporary, while there is a higher probability that faults on UGC sections are permanent. To maintain power system reliability and security, auto-reclose (AR) schemes are typically implemented to minimize outage duration after temporary OHL faults while blocking AR for UGC faults to prevent equipment damage. AR of a hybrid UCG–OHL transmission line, therefore, requires effective identification of the faulty section. However, the different electrical characteristics of UGC and OHL sections present significant challenges to existing protection and fault location methods. This paper presents a selective AR scheme for mixed conductor circuits based on the evaluation of differential currents in multiple defined protection zones, using distributed current transformer (CT) measurements provided by passive optical sensing. Case studies are conducted with a number of different UGC–OHL configurations, and the results demonstrate that the proposed scheme can accurately identify the faulty section, enabling effective selective AR of a comprehensive range of mixed conductor circuit topologies. The proposed scheme is also more cost effective, with reduced hardware requirements compared to conventional solutions. This paper thereby validates the optimal solution for mixed circuit protection as described in CIGRE Working Group B5.23 report 587.
Keywords: auto-reclosing; mixed conductor circuit; overhead transmission lines; underground cables; multi-zone differential current protection; distributed sensing (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/6/2558/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/6/2558/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:6:p:2558-:d:1091411
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().