EconPapers    
Economics at your fingertips  
 

Design and Implementation of a Particulate Matter Measurement System for Energy-Efficient Searching of Air Pollution Sources Using a Multirotor Robot

Grzegorz Suchanek (), Roman Filipek and Andrzej Gołaś
Additional contact information
Grzegorz Suchanek: Department of Power Systems and Environmental Protection Facilities, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicz 30 Av., 30-059 Krakow, Poland
Roman Filipek: Department of Power Systems and Environmental Protection Facilities, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicz 30 Av., 30-059 Krakow, Poland
Andrzej Gołaś: Department of Power Systems and Environmental Protection Facilities, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicz 30 Av., 30-059 Krakow, Poland

Energies, 2023, vol. 16, issue 7, 1-16

Abstract: Analyzing air pollutants is of key importance for the environmental protection goals. High concentrations of particulate matter (PM) have a particularly negative impact on human life and health. The use of an autonomous multirotor flying robot (drone) for the purposes of locating PM sources requires the design of a dedicated measurement system from scratch. The aim of this study was to make the most important design decision, which is the correct localization of the inlet of the measurement system, taking into account disturbances in the flow field caused by the rotors. To achieve this, a computational model was built with the use of a finite-volume method in Ansys Fluent software. Based on its results, a novel criterion was proposed and applied. In addition to the trivial position outside the rotors on the extended arm, it gave the second location in the space limited by the rotors below the robot. Finally, a robot prototype was built, and a series of verification experiments were carried out, first indoors and then outdoors, at different levels of ambient PM concentrations with and without a pollution source. The field results were compiled as histograms and scatter plots and clearly demonstrated the validity of the adopted criterion. The determination coefficient between measured concentrations showed a stronger relationship when the rotors were operating. Furthermore, in cases with a present pollution source, higher concentrations were observed around the internal sensor, making it more suitable for the studied application.

Keywords: air pollution; particulate matter; pollution source localization; multirotor flying robot; UAV application; measurement system design; CFD; finite-volume method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/7/2959/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/7/2959/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:7:p:2959-:d:1105864

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:7:p:2959-:d:1105864