Assessment of Conservation Voltage Reduction in Distribution Networks with Voltage Regulating Distribution Transformers
Anthony Igiligi,
Armin Vielhauer,
Mathias Ehrenwirth,
Christian Hurm,
Thorsten Summ,
Christoph Trinkl and
Daniel Navarro Gevers ()
Additional contact information
Anthony Igiligi: Institute of new Energy Systems, Technische Hochschule Ingolstadt, 85049 Ingolstadt, Germany
Armin Vielhauer: Maschinenfabrik Reinhausen GmbH, 93059 Regensburg, Germany
Mathias Ehrenwirth: Institute of new Energy Systems, Technische Hochschule Ingolstadt, 85049 Ingolstadt, Germany
Christian Hurm: Maschinenfabrik Reinhausen GmbH, 93059 Regensburg, Germany
Thorsten Summ: Institute of new Energy Systems, Technische Hochschule Ingolstadt, 85049 Ingolstadt, Germany
Christoph Trinkl: Institute of new Energy Systems, Technische Hochschule Ingolstadt, 85049 Ingolstadt, Germany
Daniel Navarro Gevers: Institute of new Energy Systems, Technische Hochschule Ingolstadt, 85049 Ingolstadt, Germany
Energies, 2023, vol. 16, issue 7, 1-14
Abstract:
The application of voltage reduction in medium and low voltage grids to reduce peak power demand or energy consumption has been implemented since the 1980s using several approaches. Conservation Voltage Reduction (CVR), as one such approach, uses a voltage control device to reduce or increase the voltage setpoint on a busbar, thereby reducing or increasing the amount of active and reactive power supply in the network. Voltage regulation for CVR is always implemented according to established network planning standards in each country. Research in this field has proven that a CVR factor ( C V R f ) of 0.7–1.5 for peak demand reduction can be achieved. This is an evaluation metric of CVR. The aim of this research is to determine and validate C V R f for peak demand reduction by comparing actual results obtained during regular tap changes with other randomly distributed periods outside tap change operations, using a set of measurement data. It is important to understand CVR deployment capability by evaluating CVR potentials from historical random tap operations before a robust network-wide deployment is introduced. This research provides such guidance. It also provides a novel approach to determining tap changes from voltage measurements using a time-based algorithm. A C V R f ranging from 0.95 to 1.61 was estimated using a measurement dataset from a test field. The result of the entire evaluation shows that the C V R f are smaller during peak PV production and greater during peak demand periods. Further evaluation using statistical hypotheses testing and a control chart was used to validate the evaluation.
Keywords: conservation voltage reduction; peak power; tap change; voltage regulating distribution transformers (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/16/7/3155/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/7/3155/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:7:p:3155-:d:1112550
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().