EconPapers    
Economics at your fingertips  
 

Optimization of the Thermal Environment of Large-Scale Open Space with Subzone-Based Temperature Setting Using BEM and CFD Coupling Simulation

Qihang Zhang, Qinli Deng, Xiaofang Shan (), Xin Kang and Zhigang Ren
Additional contact information
Qihang Zhang: School of Civil Engineering and Architecture, Wuhan University of Technology, No. 122 Luoshi Road, Wuhan 430070, China
Qinli Deng: School of Civil Engineering and Architecture, Wuhan University of Technology, No. 122 Luoshi Road, Wuhan 430070, China
Xiaofang Shan: School of Civil Engineering and Architecture, Wuhan University of Technology, No. 122 Luoshi Road, Wuhan 430070, China
Xin Kang: School of Civil Engineering and Architecture, Wuhan University of Technology, No. 122 Luoshi Road, Wuhan 430070, China
Zhigang Ren: School of Civil Engineering and Architecture, Wuhan University of Technology, No. 122 Luoshi Road, Wuhan 430070, China

Energies, 2023, vol. 16, issue 7, 1-18

Abstract: A cruise ship, which has large-scale open spaces, has an uneven cabin thermal environment in the cruise public space, leading to overcooling or poor cooling issues. Therefore, optimizing the thermal environment of public spaces during a cruise should be the priority. According to the space functions of the cruise ship, the large public space is divided into three subzones: the entertainment area (Subzone I), the round-table dining area (Subzone II), and the square-table dining area (Subzone III). To create a uniform, stable, and comfortable thermal environment, this study proposes a subzone-based temperature setting approach to independently adjust the thermal environment of each subzone. Coupling simulation of building energy modeling (BEM) and computational fluid dynamics (CFD) was adopted in this study to determine proper temperature setpoints of the subzones under different occupancy rates. The results indicate that, compared with a single-temperature setpoint for the entire public space, the subzone-based temperature setpoints could achieve a uniform thermal environment. The average temperature difference among the three subzones was 0.68 °C. Moreover, the airflow between two adjacent subzones considerably affected the BEM results of energy consumption of the air-conditioning system.

Keywords: building energy modeling; CFD simulations; temperature field; mass exchange rates (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/16/7/3214/pdf (application/pdf)
https://www.mdpi.com/1996-1073/16/7/3214/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:16:y:2023:i:7:p:3214-:d:1114602

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:16:y:2023:i:7:p:3214-:d:1114602