Construction and Electrothermal Performance Evaluation of a Solar-Powered Emergency Shelter
Tiangang Lv,
Bing Liu,
Rujie Liu,
Li Zhu,
Yujiao Huo () and
Mingda Ji
Additional contact information
Tiangang Lv: Three Gorges Electric Energy Co, Ltd., Wuhan 430010, China
Bing Liu: Three Gorges Electric Energy Co, Ltd., Wuhan 430010, China
Rujie Liu: Three Gorges Electric Energy Co, Ltd., Wuhan 430010, China
Li Zhu: National Industry-Education Platform of Energy Storage, Tianjin University, Tianjin 300072, China
Yujiao Huo: APEC Sustainable Energy Center, Asia-Pacific Economic Cooperation (APEC)/National Energy Administration (NEA) of China, Tianjin 300072, China
Mingda Ji: National Industry-Education Platform of Energy Storage, Tianjin University, Tianjin 300072, China
Energies, 2023, vol. 17, issue 1, 1-17
Abstract:
Power outages and poor thermal conditions are common in emergency shelters. In light of this, a novel design for a solar-powered emergency shelter (SPES) with flexible photovoltaics is proposed and investigated in this paper. Firstly, the space and structure of SPES are designed based on ergonomic and easy open-and-close requirements. Then, considering the finishing strength of the building and the convenience and economy of the processing design, the construction of solid models using a 1:2 equal scale, and three double-top SPES were developed, in which internal roofs are canvas, polyethylene(PE), and polyvinyl chloride(PVC). Finally, measurements and ANSYS-Fluent simulations are employed for testing the dynamic fluctuation of the electrothermal performance of SPES. It is found that the maximum differences between the inner roof interior side temperature (IRIST) and the outdoor ambient environment temperature (OAET) for S ref , D sc , D pe , and D pvc are 33.3 °C, 32.9 °C, 28.1 °C, and 25.9 °C, respectively, in winter conditions in China cold zone. The optimized design parameters of SPES in Poso City, Indonesia, characterized by equatorial humid climatic conditions, recommended that the air interlayer be 0.2 meters thick and the exhaust air volume be 0.3 m 3 /s. Mechanical ventilation coupled with evaporative conditioners can further reduce indoor temperatures effectively. This research offers a novel solution to the problems of indoor thermal environments and power outages for post-disaster resettlement.
Keywords: solar-powered emergency shelter (SPES); design and construction; electrothermal performance; measurements and simulations (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/1/118/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/1/118/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2023:i:1:p:118-:d:1307026
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().