EconPapers    
Economics at your fingertips  
 

Enhanced Efficiency on ANPC-DAB through Adaptive Model Predictive Control

Adriano Nardoto, Lucas Encarnação (), Walbermark Santos, Arthur Amorim, Rodrigo Fiorotti, David Molinero and Emilio Bueno
Additional contact information
Adriano Nardoto: Department of Electrical Engineering, Federal Institute of Espírito Santo (IFES), BR101 Km 58, São Mateus 29932-540, Brazil
Lucas Encarnação: Department of Electrical Engineering, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória 29075-910, Brazil
Walbermark Santos: Department of Electrical Engineering, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória 29075-910, Brazil
Arthur Amorim: Department of Electrical Engineering, Federal Institute of Espírito Santo (IFES), BR101 Km 58, São Mateus 29932-540, Brazil
Rodrigo Fiorotti: Department of Electrical Engineering, Federal Institute of Espírito Santo (IFES), BR101 Km 58, São Mateus 29932-540, Brazil
David Molinero: Department of Electronics, Alcalá University (UAH), Plaza San Diego S/N, 28801 Madrid, Spain
Emilio Bueno: Department of Electronics, Alcalá University (UAH), Plaza San Diego S/N, 28801 Madrid, Spain

Energies, 2023, vol. 17, issue 1, 1-25

Abstract: This work studies the DC-DC conversion stage in solid-state transformers (SST). The traditional two- or three-level dual active bridge (DAB) topology faces limitations in microgrid interconnection due to power and voltage limitations. For this reason, the use of multilevel topologies such as active neutral point clamped (ANPC) is a promising alternative. Additionally, the efficiency of the SSTs is a recurring concern, and reducing losses in the DC-DC stage is a subject to be studied. In this context, this work presents a new control technique based on an adaptive model- based predictive control (AMPC) to select the modulation technique of an ANPC-DAB DC-DC converter aimed at reducing losses and increasing efficiency. The single-phase shift (SPS), triangular, and trapezoidal modulation techniques are used according to the converter output power with the aim of maximizing the number of soft-switching points per cycle. The performance of the proposed control technique is demonstrated through real-time simulation and a reduced-scale experimental setup. The findings indicate the effectiveness of the AMPC control technique in mitigating voltage source perturbations. This technique has low output impedance and is robust to converter parameter variations. Prototyping tests revealed that, in steady-state, the AMPC significantly improves converter efficiency without compromising dynamic performance. Despite its advantages, the computational cost of AMPC is not significantly higher than that of traditional model predictive control (MPC), allowing for the allocation of time to other applications.

Keywords: Dual Active Bridge (DAB) converter; active neutral point clamped (ANPC); model predictive control (MPC); power electronics; switching losses; adaptive control (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/1/12/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/1/12/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2023:i:1:p:12-:d:1303238

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2023:i:1:p:12-:d:1303238