Analysis of Flexibility Potential of a Cold Warehouse with Different Refrigeration Compressors
Ehsan Khorsandnejad (),
Robert Malzahn,
Ann-Katrin Oldenburg,
Annedore Mittreiter and
Christian Doetsch
Additional contact information
Ehsan Khorsandnejad: Fraunhofer Institute for Environmental, Safety and Energy Technology UMSICHT, Osterfelder Straße 3, 46047 Oberhausen, Germany
Robert Malzahn: Fraunhofer Institute for Environmental, Safety and Energy Technology UMSICHT, Osterfelder Straße 3, 46047 Oberhausen, Germany
Ann-Katrin Oldenburg: Fraunhofer Institute for Environmental, Safety and Energy Technology UMSICHT, Osterfelder Straße 3, 46047 Oberhausen, Germany
Annedore Mittreiter: Fraunhofer Institute for Environmental, Safety and Energy Technology UMSICHT, Osterfelder Straße 3, 46047 Oberhausen, Germany
Christian Doetsch: Fraunhofer Institute for Environmental, Safety and Energy Technology UMSICHT, Osterfelder Straße 3, 46047 Oberhausen, Germany
Energies, 2023, vol. 17, issue 1, 1-22
Abstract:
The research into new approaches to shift from fossil fuels to renewable energy sources (RES) has surged as environmental issues are on the rise, and fossil fuel sources are becoming scarce. The flexibility potential of cold supply systems has been discussed widely in the literature, firstly due to their high share of electricity consumption worldwide and secondly because of their potential to store thermal energy in the form of cold energy. However, finding a clear definition of flexibility and a concise approach for its quantification is still under progress. In this work, a comprehensive definition of the flexibility of energy systems and a novel methodology for its quantification are introduced. The methodology was applied on a cold warehouse with real data regarding its cold energy demand. The cold warehouse was first modeled via oemof, which is a modular open source framework developed in Python 3.8 using a mixed integer linear programming (MILP) optimization approach. The operation optimization of the cold warehouse was conducted for three goals, namely “minimization of electricity costs”, “minimization of CO 2 emissions”, and “minimization of maximum used electric power (peak load minimization)”. Additionally, the effect of using different types of refrigeration compressors on the optimized operation of the cold warehouse was investigated. The results suggest that a cold warehouse possesses a high level of flexibility potential, which can be taken advantage of to reduce the electricity cost by up to 50%, the CO 2 emissions between 25% to 30%, and the maximum used electric power by 50%. Different compressor types produced very similar results, although their flexibility level may vary.
Keywords: flexibility; energy system; cold supply system; cold warehouse; renewable energy sources; electricity costs; CO 2 emissions; oemof; refrigeration compressors; operation optimization (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/1/85/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/1/85/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2023:i:1:p:85-:d:1305878
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().