Second-Order Sliding-Mode Control Applied to Microgrids: DC & AC Buck Converters Powering Constant Power Loads
Miguel Monsalve-Rueda,
John E. Candelo-Becerra and
Fredy E. Hoyos ()
Additional contact information
Miguel Monsalve-Rueda: Facultad de Minas, Departamento de Procesos y Energía, Universidad Nacional de Colombia, Sede Medellín, Carrera 80 No. 65-223, Robledo, Medellín 050041, Colombia
John E. Candelo-Becerra: Facultad de Minas, Departamento de Energía Eléctrica y Automática, Universidad Nacional de Colombia, Sede Medellín, Carrera 80 No. 65-223, Robledo, Medellín 050041, Colombia
Fredy E. Hoyos: Facultad de Minas, Departamento de Energía Eléctrica y Automática, Universidad Nacional de Colombia, Sede Medellín, Carrera 80 No. 65-223, Robledo, Medellín 050041, Colombia
Energies, 2024, vol. 17, issue 11, 1-18
Abstract:
Microgrids are designed to connect different types of AC and DC loads, which require robust power controllers to achieve an efficient power transfer. However, the effects of both AC and DC disturbances in the same type of controller make achieving stability a design challenge, especially in coupled systems where disturbances affect both the upstream and downstream in the microgrid. This paper presents an analysis of a second-order sliding-mode control (SOSMC) applied to a microgrid with direct-current (DC) and alternating-current (AC) power converters. The aim is to simulate the second-order sliding-mode control with buck converters that feed constant DC–DC and DC–AC power loads. The controller was tested in consideration of a unique sliding surface facing external disturbances, such as variations in the frequency of AC converters, sudden changes in upstream voltages, and constant power loads (CPL). The influence of the gain values (K) on the controller was also analyzed. The results show that the controller is robust regarding its sensitivity to external disturbances and steady-state error. However, the importance of the constant “K” in the model states that there exist K-limit values where if “K” is too low, a slowdown is presented, and the response against disturbances can be critical, and if is too high, an overshoot is presented in the output voltage.
Keywords: sliding-mode control; microgrid; buck converter; constant power load; power converter (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/11/2701/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/11/2701/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:11:p:2701-:d:1407378
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().