EconPapers    
Economics at your fingertips  
 

A Modified Variable Power Angle Control for Unified Power Quality Conditioner in a Distorted Utility Source

Krittapas Chaiyaphun, Phonsit Santiprapan () and Kongpol Areerak
Additional contact information
Krittapas Chaiyaphun: Department of Electrical and Biomedical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla 90110, Thailand
Phonsit Santiprapan: Department of Electrical and Biomedical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla 90110, Thailand
Kongpol Areerak: School of Electrical Engineering, Institute of Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand

Energies, 2024, vol. 17, issue 12, 1-20

Abstract: The distorted supply voltage degrades the control performance of a unified power quality conditioner (UPQC). This problem causes incorrect calculations in the harmonic identification and reference signal generation processes. This paper proposes a modified harmonic identification of the UPQC. The reference compensating current calculation for the shunt active power filter (shunt APF) is developed using the sliding window with the Fourier analysis (SWFA) method. In addition, the variable power angle control (PAC) is applied to operate the reference signal generation of the series APF and the shunt APF of the UPQC. Under the distorted voltage and nonlinear load conditions, the proposed approach can provide accurate reference compensating signals and successfully share the load reactive power compensation between the shunt APF and the series APF. In this work, a three-phase, three-wire power system with linear and nonlinear loads was implemented. The proposed method was validated using the processor-in-the-loop technique on an eZdsp™ F28335 board and the MATLAB/Simulink program. The testing results indicated that SWFA has excellent filtering performance and enhances harmonic identification compared to the operation without any filter or with low pass filters (LPF). With the proposed approach, the percentage of total harmonic distortion of voltage and current could be maintained within the IEEE519-2022 standard, and the magnitude of the RMS voltage across the load was in the recommended range specified by ANSI C84.1-2016.

Keywords: unified power quality conditioner; power angle control; sliding window with Fourier analysis; distorted utility source (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/12/2830/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/12/2830/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:12:p:2830-:d:1411390

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:12:p:2830-:d:1411390