EconPapers    
Economics at your fingertips  
 

Optimization of the Joint Operation of an Electricity–Heat–Hydrogen–Gas Multi-Energy System Containing Hybrid Energy Storage and Power-to-Gas–Combined Heat and Power

Jun Yang, Linjun Zeng (zenglj23@csust.edu.cn), Kangjie He, Yongguo Gong, Zhenhua Zhang and Kun Chen
Additional contact information
Jun Yang: School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410000, China
Linjun Zeng: School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410000, China
Kangjie He: School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410000, China
Yongguo Gong: School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410000, China
Zhenhua Zhang: School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410000, China
Kun Chen: School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410000, China

Energies, 2024, vol. 17, issue 13, 1-19

Abstract: With the continuous development of hydrogen storage systems, power-to-gas (P2G) and combined heat and power (CHP), the coupling between electricity–heat–hydrogen–gas has been promoted and energy conversion equipment has been transformed from an independent operation with low energy utilization efficiency to a joint operation with high efficiency. This study proposes a low-carbon optimization strategy for a multi-energy coupled IES containing hydrogen energy storage operating jointly with a two-stage P2G adjustable thermoelectric ratio CHP. Firstly, the hydrogen energy storage system is analyzed to enhance the wind power consumption ability of the system by dynamically absorbing and releasing energy at the right time through electricity–hydrogen coupling. Then, the two-stage P2G operation process is refined and combined with the CHP operation with an adjustable thermoelectric ratio to further improve the low-carbon and economic performance of the system. Finally, multiple scenarios are set up, and the comparative analysis shows that the addition of a hydrogen storage system can increase the wind power consumption capacity of the system by 4.6%; considering the adjustable thermoelectric ratio CHP and the two-stage P2G, the system emissions reduction can be 5.97% and 23.07%, respectively, and the total cost of operation can be reduced by 7.5% and 14.5%, respectively.

Keywords: hydrogen energy storage; two-stage P2G; adjustable thermoelectric ratio (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/13/3144/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/13/3144/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:13:p:3144-:d:1422275

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager (indexing@mdpi.com).

 
Page updated 2024-12-28
Handle: RePEc:gam:jeners:v:17:y:2024:i:13:p:3144-:d:1422275