EconPapers    
Economics at your fingertips  
 

Stability Control of Grid-Connected Converter Considering Phase-Locked Loop Frequency Coupling Effect

Ye Zhang, Haibo Pen () and Xiaoyu Zhang
Additional contact information
Ye Zhang: Department of Automation, Taiyuan Institute of Technology, Taiyuan 030000, China
Haibo Pen: School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Xiaoyu Zhang: Mining Big Data Institute, China Coal Research Institute, Beijing 100013, China

Energies, 2024, vol. 17, issue 14, 1-18

Abstract: Given the problems that the phase-locked loop frequency coupling effect (PLL-FCE) in a weak grid reduces the quality of the output current waveform and brings challenges to maintaining a steady running of the grid-connected converter (GCC), this paper analyzes the coupling relationship between the FCE of the PLL, grid impedance and the output impedance of GCCs under a weak grid. It elucidates the role of the above coupling relationships in system stability and then proposes a stability optimization control method. Firstly, this paper delves into the frequency coupling phenomenon and its coupling mechanism in GCCs operating within weak grid conditions. Through analysis using small signal disturbance, it elucidates the significance of the PLL-FCE, particularly in medium- and low-frequency ranges, by establishing the coupling admittance model. Secondly, it presents the output impedance model for a three-phase LCL-type GCC, incorporating the characteristics of PLL frequency coupling. This model elucidates the interplay between the GCC’s output impedance, the PLL-FCE and the grid impedance. It also unveils the impact of the PLL-FCE on system stability in weak grid scenarios. Building upon these insights, this paper proposes an enhanced PLL based on the Second-Order Generalized Integrator (SOGI). It provides a detailed parameter design process for implementing these improved PLL structures. Finally, the study conducts simulation and experiment verification under weak grid conditions. The findings indicate that the PLL-FCE indeed undermines the stability of GCCs in the weak grid, with this effect becoming more pronounced as the grid impedance increases. However, the implementation of the SOGI-PLL successfully mitigates the adverse impact of the PLL-FCE on the stability of the converter–weak grid interactive system, thereby enhancing the adaptability of GCCs to weak grid environments.

Keywords: frequency coupling effect; grid-connected converter; stability; grid impedance; SOGI-PLL (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/14/3438/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/14/3438/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:14:p:3438-:d:1433952

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:14:p:3438-:d:1433952