EconPapers    
Economics at your fingertips  
 

Uninterruptible Power Supply Topology Based on Single-Phase Matrix Converter with Active Power Filter Functionality

Muhammad Shawwal Mohamad Rawi, Rahimi Baharom () and Mohd Amran Mohd Radzi
Additional contact information
Muhammad Shawwal Mohamad Rawi: School of Electrical Engineering, College of Engineering, Universiti Teknologi MARA (UiTM), Shah Alam 40450, Malaysia
Rahimi Baharom: School of Electrical Engineering, College of Engineering, Universiti Teknologi MARA (UiTM), Shah Alam 40450, Malaysia
Mohd Amran Mohd Radzi: Advanced Lightning, Power and Energy Research (ALPER), Universiti Putra Malaysia (UPM), Serdang 43400, Malaysia

Energies, 2024, vol. 17, issue 14, 1-36

Abstract: This study introduces a novel uninterruptible power supply (UPS) configuration that integrates active power filter (APF) capabilities within a single-phase matrix converter (SPMC) framework. Power disruptions, particularly affecting critical loads, can lead to substantial economic damages. Historically, conventional UPS systems utilized dual separate converters to function as a rectifier and an inverter, without incorporating any power factor correction (PFC) mechanisms. Such configurations suffered from diminished power density, compromised reliability, and spatial limitations. To address these issues, this research proposes an enhanced UPS design that incorporates APF features into the SPMC. The focus of this investigation is on the efficiency of alternating current (AC) to direct current (DC) conversion and the reverse process utilizing this advanced UPS model. The SPMC is selected to supplant the rectifier and inverter units traditionally employed in UPS architectures. A novel integrated switching strategy is formulated to facilitate the operation of the UPS in either rectifier (charging) or inverter (discharging) modes, contingent upon the operational state. The performance and efficacy of the devised circuit design and switching technique are substantiated through simulations conducted in MATLAB/Simulink 2019 and empirical evaluations using a test rig. The findings demonstrate that the voltage generated is sinusoidal and synchronized with the supply current, thereby minimizing the total harmonic distortion (THD) and enhancing both the power factor and the transition efficiency of the UPS system between its charging and discharging states.

Keywords: single-phase matrix converter; uninterruptible power supply; pulse width modulation; rectifier; inverter (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/14/3441/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/14/3441/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:14:p:3441-:d:1434070

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:14:p:3441-:d:1434070