Evaluation of Prediction Model for Compressor Performance Using Artificial Neural Network Models and Reduced-Order Models
Hosik Jeong,
Kanghyuk Ko,
Junsung Kim,
Jongsoo Kim,
Seongyong Eom,
Sangkyung Na () and
Gyungmin Choi ()
Additional contact information
Hosik Jeong: Graduate School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
Kanghyuk Ko: Graduate School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
Junsung Kim: Graduate School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
Jongsoo Kim: R&D Center, LG Electronics, Seoul 06763, Republic of Korea
Seongyong Eom: Center for Advanced Air-Conditioning Refrigeration and Energy, Pusan National University, Busan 46241, Republic of Korea
Sangkyung Na: Center for Advanced Air-Conditioning Refrigeration and Energy, Pusan National University, Busan 46241, Republic of Korea
Gyungmin Choi: Department of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
Energies, 2024, vol. 17, issue 15, 1-12
Abstract:
In order to save the time and material costs associated with refrigeration system performance evaluations, a reduced-order model (ROM) using highly accurate numerical analysis results and some experimental values was developed. To solve the shortcomings of these traditional methods in monitoring complex systems, a simplified reduced-order system model was developed. To evaluate the performance of the refrigeration system compressor, the temperature of several points in the system where the compressor actually operates was measured, and the measured values were used as input values for ROM development. A lot of raw data to develop a highly accurate ROM were acquired from a VRF system installed in a building for one year, and in this study, specific operating conditions were selected and used as input values. In this study, the ROM development process can predict the performance of compressors used in air conditioning systems, and the research results on optimizing input data required for ROM generation were observed. The input data are arranged according to the design of experiments (DOE), and the accuracy of ROM according to data arrangement is compared through the experiment results.
Keywords: reduced-order model; HVAC compressor; prediction method; response surface methodology; minimal dataset (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/15/3686/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/15/3686/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:15:p:3686-:d:1443491
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().