EconPapers    
Economics at your fingertips  
 

Experimental and Numerical Study on Air Cooling System Dedicated to Photovoltaic Panels

Maksymilian Homa, Krzysztof Sornek () and Wojciech Goryl
Additional contact information
Maksymilian Homa: Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland
Krzysztof Sornek: Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland
Wojciech Goryl: Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland

Energies, 2024, vol. 17, issue 16, 1-21

Abstract: The efficiency of solar systems, in particular photovoltaic panels, is typically low. Various environmental parameters affect solar panels, including sunlight, the ambient and module surface temperatures, the wind speed, humidity, shading, dust, the installation height, etc. Among others, the key players are indeed solar irradiance and temperature. The higher the temperature is, the higher the short-circuit current is, and the lower the open-circuit voltage is. The negative effect of lowering the open-circuit voltage is dominant, consequently lowering the power of the photovoltaic panels. Passive or active cooling systems can be provided to avoid the negative effect of temperature. This paper presents a prototype of an active cooling system dedicated to photovoltaics. The prototype of such a system was developed at the AGH University of Kraków and tested under laboratory conditions. The proposed system is equipped with air fans mounted on a plate connected to the rear part of a 70 Wp photovoltaic panel. Different configurations of the system were tested, including different numbers of fans and different locations of the fans. The artificial light source generated a irradiation value of 770 W/m 2 . This value was present for every variant tested in the experiment. As observed, the maximum power generated in the photovoltaic panel under laboratory conditions was approx. 47.31 W. Due to the temperature increase, this power was reduced to 40.09 W (when the temperature of the uncooled panel surface reached 60 °C). On the other hand, the power generated in the photovoltaic panel equipped with the developed cooling system was approx. 44.37 W in the same conditions (i.e., it was higher by 10.7% compared to that of the uncooled one). A mathematical model was developed based on the results obtained, and simulations were carried out using the ANSYS Workbench software. After the validation procedure, several configurations of the air cooling system were developed and analyzed. The most prominent case was chosen for additional parametrical analysis. The optimum fan orientation was recognized: a vertical tilt of 7° and a horizontal tilt of 10°. For the tested module, this modification resulted in a cost-effective system (a net power increase of ~3.1%).

Keywords: solar energy; photovoltaics; PV; air cooling of PV panels; parametric optimization; CFD (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/16/3949/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/16/3949/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:16:p:3949-:d:1453099

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:16:p:3949-:d:1453099