Experimental Investigation of R404A Indirect Refrigeration System Applied Internal Heat Exchanger: Part 1—Coefficient of Performance Characteristics
Min-Ju Jeon and
Joon-Hyuk Lee ()
Additional contact information
Min-Ju Jeon: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
Joon-Hyuk Lee: Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
Energies, 2024, vol. 17, issue 16, 1-16
Abstract:
In this study, the performance characteristics of an R404A indirect refrigeration system (IRS) applied to an internal heat exchanger (IHX) is evaluated for supermarkets and hypermarkets. In a direct expansion system, R404A is the primary refrigerant and R744, a brine, is the secondary fluid. While there are abundant studies analyzing the theoretical performance of IRS, experimental research on IRS is lacking, and there are no papers that address the results of changes in the IHX in detail. In this study, the results achieved by modifying various parameters are experimentally evaluated to provide fundamental data for designing the optimal IRS. In the main results, looking at the trend of the increase in IHX efficiency, the change is very minimal when the efficiency is above 50%, so it is ideal to apply an IHX efficiency of about 50% considering economics and COP, etc. Applying the results in this study enables the operation and maintenance of IRSs as an eco-friendly system by achieving energy efficiency through optimizing the system coefficient of performance and securing economic feasibility by minimizing the R404A charging amount of the refrigeration cycle. To serve supermarkets and hypermarkets, R744 as a secondary fluid may help to realize an ecologically friendly, compact IRS system with a high heat transfer coefficient that can operate at low temperatures (−35 to 5 °C).
Keywords: carbon dioxide; R744; R404A; coefficient of performance (COP); indirect refrigeration system (IRS); internal heat exchanger (IHX) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/16/4127/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/16/4127/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:16:p:4127-:d:1459301
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().