Analysis of Indoor Air Quality and Fresh Air Energy Consumption Based on Students’ Learning Efficiency under Different Ventilation Methods by Modelica
Xu Li,
Jingyi Xiong,
Qifan Zhang and
Qiang Wang ()
Additional contact information
Xu Li: Wuhan Second Ship Design and Research Institute, Wuhan 430061, China
Jingyi Xiong: Wuhan Second Ship Design and Research Institute, Wuhan 430061, China
Qifan Zhang: School of Navel Architecture, Ocean and Energy Power Engineering, Wuhan University of Technology, Wuhan 430063, China
Qiang Wang: School of Navel Architecture, Ocean and Energy Power Engineering, Wuhan University of Technology, Wuhan 430063, China
Energies, 2024, vol. 17, issue 18, 1-25
Abstract:
This paper aimed to explore a suitable ventilation method at a lower cost of energy to pursue a high learning efficiency based on the characteristics of a Chinese student group and campus building. Firstly, the model was established by Modelica and a good agreement between the numerical simulation and the results by CONTAM 3.4.0.3 was obtained. Secondly, the effects of the fixed window-opening ratio method (FWM), switch control window-opening ratio method (SCM), and automatic control window-opening ratio method (ACM) on CO 2 concentration, indoor air temperature, and the heating capacity of air conditioning were investigated. The results showed that, when the FWM with 0% opening or 20% opening was adopted, the indoor CO 2 concentration (ICC) was higher than the limit value of the classroom air quality standard, which was 1000 ppm. When the fixed window-opening ratio was greater than 40%, the indoor air temperature could not be controlled at the set value of 18 °C, which presented bad indoor thermal comfort. Meanwhile, when the ACM was adopted, the duration to meet good indoor thermal comfort was 57.17% higher than that of the SCM. However, both of them could maintain the average ICC below the set value in the class. Lastly, the fresh air energy consumption under different ventilation methods was compared. When the design temperature was 13.5 °C, it could be revealed that the fresh air energy consumption under the ACM, SCM, and FWM with 40% opening was 46.58%, 48.38%, and 51.26% lower than those at 18 °C. In summary, it was recommended to set the design temperature of the classroom at 13.5 °C, and the ACM was suggested as a suitable ventilation method to provide fresh air for the classroom.
Keywords: thermal comfort; indoor air quality; learning efficiency; energy consumption; ventilation method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/18/4613/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/18/4613/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:18:p:4613-:d:1478491
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().