Effect of Reactive Power Generation in Photovoltaic Installations on the Voltage Value at the Inverter Connection Point
Grzegorz Hołdyński,
Zbigniew Skibko (),
Andrzej Borusiewicz (),
Andrzej Marczuk and
Adam Koniuszy
Additional contact information
Grzegorz Hołdyński: Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
Zbigniew Skibko: Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
Andrzej Borusiewicz: Department of Agronomy, Modern Technology and Informatics, International Academy of Applied Sciences in Lomza, 18-402 Lomza, Poland
Andrzej Marczuk: Department of Agricultural, Forestry and Transport Machines, University of Life Sciences in Lublin, Głęboka 28, 20-612 Lublin, Poland
Adam Koniuszy: Department of Renewable Energy Engineering, West Pomeranian University of Technology in Szczecin, Pawla VI 1, 71-459 Szczecin, Poland
Energies, 2024, vol. 17, issue 19, 1-12
Abstract:
Worldwide, photovoltaic installations are making an increasing contribution to electric energy generation. These are power-unstable sources due to the rapid and frequent change in insolation. As a result, a common problem noted in low-voltage power grids is that the permitted voltage values at the source connection point are exceeded. There are several methods of limiting the voltage values present at the inverter. One of them is the generation of reactive power in a photovoltaic installation. In the literature, one can find many relationships that allow one to determine the increase in voltage caused by the change in reactive power, where the imaginary part of the voltage loss is omitted as insignificant. The authors’ research has shown that this can lead to significant errors. Omitting the imaginary value causes the determined values to be even more than 4.5 times smaller—these differences increase with the length of the line. The analyses carried out by the authors show that the determination of voltage increments with and without taking into account the imaginary part of the voltage loss in the calculations differs from the values determined via computer simulation (failure to take into account the imaginary part results in calculated values of voltage increase being lower than the values determined via a computer by about 40% on average).
Keywords: voltage regulation; reactive power; power line; overvoltage (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/19/4863/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/19/4863/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:19:p:4863-:d:1487643
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().