Active Support Pre-Synchronization Control and Stability Analysis Based on the Third-Order Model of Synchronous Machine
Chuang Liu,
Yuemei Zhi,
Zhida Su,
Zedong Yang,
Limin Yin (),
Jiawei Man and
Yuze Yang
Additional contact information
Chuang Liu: School of Electrical Engineering, Northeast Electric Power University, Jilin City 132013, China
Yuemei Zhi: School of Electrical Engineering, Northeast Electric Power University, Jilin City 132013, China
Zhida Su: China Electric Power Research Institute Co., Ltd., Haidian District, Beijing 100192, China
Zedong Yang: China Electric Power Research Institute Co., Ltd., Haidian District, Beijing 100192, China
Limin Yin: School of Electrical Engineering, Northeast Electric Power University, Jilin City 132013, China
Jiawei Man: School of Electrical Engineering, Northeast Electric Power University, Jilin City 132013, China
Yuze Yang: School of Electrical Engineering, Northeast Electric Power University, Jilin City 132013, China
Energies, 2024, vol. 17, issue 20, 1-18
Abstract:
When traditional grid-forming converters directly participate in the grid-connected operation of the power grid, due to the lack of a pre-synchronization control system, the voltage amplitude and initial phase on both sides of the grid-connected point will deviate, resulting in voltage and current distortion during grid-connected mode. An active support phase-locked loop free pre-synchronization control strategy based on the third-order model of a synchronous generator is proposed to address the grid-connected problem of the grid-forming converter mentioned above. First, a model of active support control with frequency integral feedback at small signal levels was constructed. The root locus method was employed to examine how system parameters affect the stability of the active support control system. Second, by adding phase pre-synchronization controllers and amplitude pre-synchronization controllers to the active frequency loop and excitation voltage loop of the third-order model, it was ensured that the frequency, phase, and voltage amplitude of the unit are consistent with the power grid, achieving a fast and smooth grid-connected mode of the unit. Finally, by using a DC source to simulate all types of new energy power generation equipment, the active support pre-synchronization control system based on the three-order model of synchronous generator is built in the MATLAB/Simulink simulation environment, and the accuracy and effectiveness of the control strategy in this paper is verified.
Keywords: pre-synchronization; active support; third-order model of synchronous generator; voltage source converter; inertia (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/20/5072/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/20/5072/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:20:p:5072-:d:1497036
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().