Abstract: DC link capacitors (DCLCs) are key devices in converters. The relative humidity affects the performance of the elements of a DCLC. Currently, there are relatively few studies on the effect of relative humidity on the electrical characteristics of the elements of DCLCs during the production process. This study describes the effects and the control of the relative humidity in the production process. For this purpose, a DCLC component withstand voltage test platform and a DCLC component aging test platform were established. The voltage withstand tests were conducted during different processes and at different relative humidities, and life aging tests were conducted at different relative humidities and different storage times. The results show that after the winding and metal-spraying processes, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH were very close to that of the components at 3000 VDC; after the heat-setting process, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH showed a decreasing tendency compared with the level of the components at 3000 VDC. Regarding the samples, after the heat-setting process, stored at 30% RH and 60% RH for 24 h, 96 h, 168 h, 240 h, and 336 h and 2000 h of the aging tests, the capacitance decreases monotonically as the storage time is increased but never exceeds 3%, and the capacitance change decreases as the relative humidity increases. This study can provide important guidance for the humidity control of various processes in the production of DCLCs.

Keywords: DC link capacitor; air humidity; relative humidity; components; life aging test; withstand voltage test (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/20/5081/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/20/5081/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:20:p:5081-:d:1497463

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:20:p:5081-:d:1497463