EconPapers    
Economics at your fingertips  
 

Overvoltage Suppression Strategy for VSG-Based DFIGs Under Commutation Failures of HVDC Transmission Systems

Shuyi Wang, Qicai Wang, Zhijie Zeng, Wei Jiang, Jinyu Chen and Zhijun Wang ()
Additional contact information
Shuyi Wang: School of Electrical Engineering, Shandong University, Jinan 250061, China
Qicai Wang: School of Electrical Engineering, Shandong University, Jinan 250061, China
Zhijie Zeng: State Grid Fujian Electric Power Co., Ltd., Fuzhou 350003, China
Wei Jiang: State Grid Fujian Electric Power Co., Ltd., Fuzhou 350003, China
Jinyu Chen: State Grid Fujian Electric Power Co., Ltd., Fuzhou 350003, China
Zhijun Wang: School of Electrical Engineering, Shandong University, Jinan 250061, China

Energies, 2024, vol. 17, issue 23, 1-14

Abstract: Virtual synchronous generator (VSG) control, which can provide inertia output, damp power oscillations, and offer frequency and voltage support to power grids, has become a growing trend in the control field of wind power generation. As a new technology, there are still challenges that VSG control has not solved well, such as transient overvoltage suppression. A kind of transient overvoltage, which often occurs during the commutation failures of HVDC transmission systems, will trigger a mass of wind turbine generators (WTGs) disconnecting from grids. To reduce the grid-disconnection risk of the virtual synchronous generator control-based doubly fed induction generators (VSG-DFIGs), this paper first analyzes the mechanism of the automatic voltage regulation (AVR) control usually employed by VSG-DFIGs, then proposes measures to suppress the transient overvoltage. To solve the problem of the reactive power response lag issued by VSG-DFIGs, which will further aggravate the transient overvoltage in continuous low and high voltage faults, the time constant of the AVR control is switched. To fully exploit the potential of the DFIGs’ reactive power support, the droop coefficient of the AVR control is switched during the abnormal voltage stages. The switched droop coefficient will change the rotor excitation current magnitude, thus adjusting the internal potential of a DFIG, finally better supporting or suppressing the terminal voltage during the low or high voltage periods. Simulation results based on the DIgSILENT/PowerFactory platform demonstrate that the proposed method can effectively suppress the transient overvoltage that occurs in continuous low and high voltage events caused by the commutation failures of HVDC transmission systems, reducing the number of WTGs disconnecting from the grids.

Keywords: automatic voltage regulation (AVR); doubly fed induction generator (DFIG); transient overvoltage suppression; virtual synchronous generator (VSG); voltage ride-through (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/23/5989/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/23/5989/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:23:p:5989-:d:1531796

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:23:p:5989-:d:1531796