Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads
Nicholas Truster (),
Jamie S. Ervin,
Abdeel Roman and
Jeff Monfort
Additional contact information
Nicholas Truster: Air Force Research Laboratory, 2450 D St. Building 20, Wright-Patterson AFB, Wright, OH 45433-7251, USA
Jamie S. Ervin: Department of Mechanical and Aerospace Engineering, University of Dayton, 300 College Park, Dayton, OH 45469-0044, USA
Abdeel Roman: Air Force Research Laboratory, 2450 D St. Building 20, Wright-Patterson AFB, Wright, OH 45433-7251, USA
Jeff Monfort: University of Dayton Research Institute, Department of Mechanical and Aerospace Engineering, University of Dayton, 300 College Park, Dayton, OH 45469-0044, USA
Energies, 2024, vol. 17, issue 24, 1-20
Abstract:
As avionics become more power dense, electronic device cooling has become a significant barrier to aircraft integration. A mechanically pumped two-phase loop (MPTL) is a thermal subsystem that enables near isothermal evaporator operation, which is desirable for electronics cooling. The goal of this study was to integrate an MPTL with a pressure-controlled accumulator and model a predictive control technique to demonstrate improvements for transient, isothermal evaporator operation for MPTLs under pulsed evaporator heat loads. The model predictive controller enables active control of MPTL compressible volume, which has not been demonstrated for pulsed evaporator heat loads. Experimental data were collected to validate a representative numerical model. A pressure-controlled accumulator was added to an MPTL to experimentally characterize the system thermodynamic response for three pulsed evaporator heat loads. Two statistical methods were used to assess the numerical model agreement with the experimental results. Under pulsed evaporator heat loads, the mean percent error agreed within 3.45% and the mean average percent error agreed within 0.74% for the three pulsed evaporator heat loads. Finally, a traditional proportional–integral (PI) controller and an advanced model predictive controller were developed and integrated into the validated numerical model. Both control methods were evaluated for an expanded set of evaporator heat load profiles to analyze transient behavior. For evaporator heat profiles with high heat transfer rates, the model predictive controller can maintain a target ±2 K refrigerant temperature at the evaporator exit throughout the evaporator heat load duration, whereas the PI-controlled MPTL cannot. Through this work, active control of a pressure-controlled accumulator within an MPTL is shown to improve refrigerant isothermal (±2 K) operation when compared to a traditional control technique.
Keywords: two-phase flow; aircraft environmental control; mechanically pumped two-phase loop; pressure-controlled accumulator (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/24/6347/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/24/6347/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:24:p:6347-:d:1545519
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().