EconPapers    
Economics at your fingertips  
 

Adaptive Hybrid Overcurrent Protection Scheme with High Shares of Distributed Energy Resources

Gourab Banerjee (), Christian Hachmann, Jan Lipphardt, Nils Wiese and Martin Braun
Additional contact information
Gourab Banerjee: Fraunhofer Institute for Energy Economics and Energy System Technology IEE, Joseph-Beuys-Straße 8, 34117 Kassel, Germany
Christian Hachmann: Fraunhofer Institute for Energy Economics and Energy System Technology IEE, Joseph-Beuys-Straße 8, 34117 Kassel, Germany
Jan Lipphardt: Department of Energy Management and Power System Operation, University of Kassel, 34117 Kassel, Germany
Nils Wiese: Fraunhofer Institute for Energy Economics and Energy System Technology IEE, Joseph-Beuys-Straße 8, 34117 Kassel, Germany
Martin Braun: Fraunhofer Institute for Energy Economics and Energy System Technology IEE, Joseph-Beuys-Straße 8, 34117 Kassel, Germany

Energies, 2024, vol. 17, issue 24, 1-25

Abstract: In this research paper, an adaptive and intelligent protection scheme is developed that brings selectivity and sensitivity to the conventional overcurrent relays considering the changes in grid topologies, changes in grid operation modes, and changes in short-circuit behavior due to the contributions from distributed energy resources in the medium-voltage distribution grids. A quasi-static medium-voltage benchmark grid model is used in the Python-based power system tool pandapower. Definite-time overcurrent relay devices are extended with a communication signal-based tripping scheme suitable for a decentralized communication architecture. Current phasor angles are compared between two primary relays and the result is fed into a tripping logic to achieve selectivity of the primary protection. Furthermore, communication between the primary and backup relays is established, extending the communication signal-based tripping scheme. It analyzes in which cases the proposed communication-based protection scheme’s ability to isolate the faulty section after short-circuit events is comparable to conventional schemes based on distance relays that require additional voltage measurements or differential relays that require dedicated high-speed communication. Therefore, the pre-existing and installed communication capabilities can be used to avoid the need for additional measurement hardware or communication technology.

Keywords: adaptive protection; overcurrent relays; ICT-based protection scheme; ICT architecture; distributed energy resources; pandapower; power system protection (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/24/6422/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/24/6422/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:24:p:6422-:d:1548420

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19