Numerical Study on Peak Shaving Performance of Combined Heat and Power Unit Assisted by Heating Storage in Long-Distance Pipelines Scheduled by Particle Swarm Optimization Method
Haoran Ju,
Yongxue Wang,
Yiwu Feng and
Lijun Zheng ()
Additional contact information
Haoran Ju: Heating Research Center, Huadian Electric Power Research Institute, 2 Xiyuan Nine Road, Hangzhou 310030, China
Yongxue Wang: Heating Research Center, Huadian Electric Power Research Institute, 2 Xiyuan Nine Road, Hangzhou 310030, China
Yiwu Feng: Heating Research Center, Huadian Electric Power Research Institute, 2 Xiyuan Nine Road, Hangzhou 310030, China
Lijun Zheng: Heating Research Center, Huadian Electric Power Research Institute, 2 Xiyuan Nine Road, Hangzhou 310030, China
Energies, 2024, vol. 17, issue 2, 1-18
Abstract:
Thermal energy storage in long-distance heating supply pipelines can improve the peak shaving and frequency regulation capabilities of combined heat and power (CHP) units participating in the power grid. In this study, a one-dimensional numerical model was established to predict the thermal lag in long-distance pipelines at different scale levels. The dynamic response of the temperature at the end of the heating pipeline was considered. For the one-way pipe lengths of 10 km, 15 km and 20 km, the response times of the temperature at the distal end were 2.33 h, 2.94 h and 3.54 h, respectively. The longer the flow period, the further the warming-up time is delayed. An optimization scheduling approach was also created to illustrate the peak shaving capabilities of a CHP unit combined with a long-distance pipeline thermal energy storage component. It was demonstrated that the maximum heating load of the unit increased up to 503.08 MW, and the heating load could be expanded in the range of 17.88 MW to 203.76 MW at the minimum electric load of the unit of 104.08 MW. Finally, the particle swarm optimization method was adopted to guide the operating strategy through a whole day to meet both the electric power and heating power requirements. For the optimized case, the comprehensive energy utilization efficiency and the exergy efficiency increase to 64.4% and 56.73%. The thermal energy storage applications based on long-distance pipelines were simulated quantitively and proved to be effective in promoting the operational flexibility of the CHP unit.
Keywords: thermal inertia; long-distance pipeline; peak shaving; combined heat and power unit; particle swarm optimization (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/2/492/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/2/492/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:2:p:492-:d:1322309
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().