EconPapers    
Economics at your fingertips  
 

Investigation of the Performance of Battery Thermal Management Based on Direct Refrigerant Cooling: Simulation, Validation of Results, and Parametric Studies

Suparat Jamsawang, Saharat Chanthanumataporn (), Kittiwoot Sutthivirode and Tongchana Thongtip ()
Additional contact information
Suparat Jamsawang: Automotive Innovation Laboratory, Mechanical and Automotive Engineering Program, The Sirindhorn International Thai-German Graduate School of Engineering (TGGS), King Mongkut’s University of Technology North Bangkok, Bangkok 10800, Thailand
Saharat Chanthanumataporn: Automotive Innovation Laboratory, Mechanical and Automotive Engineering Program, The Sirindhorn International Thai-German Graduate School of Engineering (TGGS), King Mongkut’s University of Technology North Bangkok, Bangkok 10800, Thailand
Kittiwoot Sutthivirode: Advanced Refrigeration and Air Conditioning Laboratory (ARAC), Department of Teacher Training in Mechanical Engineering, King Mongkut’s University of Technology North Bangkok, Bangkok 10800, Thailand
Tongchana Thongtip: Advanced Refrigeration and Air Conditioning Laboratory (ARAC), Department of Teacher Training in Mechanical Engineering, King Mongkut’s University of Technology North Bangkok, Bangkok 10800, Thailand

Energies, 2024, vol. 17, issue 2, 1-24

Abstract: This study proposes a simulation technique for investigating a battery thermal management system based on direct refrigerant cooling (BTMS-DRC). The main focus is to investigate the temperature uniformity and working temperature of the module housing. The simulation technique employs a finite element method for a combined conduction–convection heat transfer to predict the module housing temperature. The refrigerant side is based on two-phase flow evaporation, which is represented by the convection heat transfer under a certain refrigerant saturation temperature. The real BTMS-DRC, which is based on the dual-evaporator vapor compression refrigeration system, is constructed for experimentation with the test bench. The simulated result is validated with the experimental results to ensure correction of the modelling. Error rates of approximately 2.9–7.2% are noted throughout the specified working conditions. The BTMS can produce temperatures of less than 35 °C under conditions where 80–320 W heat is generated. The difference in the temperature of the module is around 1.7–4.2 °C. This study also investigates the impact of heat generation, the convection heat transfer coefficient (h ref ), the refrigerant saturation temperature, and thermal conductivity on the module’s temperature. The thermal conductivity ranges from 25 to 430 W/m·K, while the h ref ranges from 80 to 400 W/m 2 ·K.

Keywords: BTMS; refrigerant cooling; evaporation heat transfer; EVs (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/2/543/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/2/543/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:2:p:543-:d:1324313

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:2:p:543-:d:1324313