Measurement of High-Frequency Voltage Harmonics above 2 kHz in High-Voltage Networks
Imanka Dewayalage (),
Duane A. Robinson,
Sean Elphick and
Sarath Perera
Additional contact information
Imanka Dewayalage: Australian Power Quality Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
Duane A. Robinson: Australian Power Quality Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
Sean Elphick: Australian Power Quality Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
Sarath Perera: Australian Power Quality Research Centre, University of Wollongong, Wollongong, NSW 2522, Australia
Energies, 2024, vol. 17, issue 4, 1-35
Abstract:
Large-scale renewable energy plants, flexible AC (alternating current) and high voltage DC (direct current) transmission systems, and modern consumer devices utilize power electronics that tend to increase harmonic emissions. Furthermore, such emissions are nowadays known to exceed the traditional 2 kHz range typically considered for harmonic analysis. However, the accuracy of such harmonic measurements in medium and high voltage networks is questionable due to the lack of accuracy specifications for the respective instrument transformers that are being used in the measurement chain. Therefore, the motivation of this study is to review the existing techniques for measuring high-frequency voltage harmonics, i.e., those in the range 2–9 kHz, in medium-, high-, and extra high-voltage electricity networks, where most large-scale power electronic converters are being connected. Different transducer types are compared in terms of measurement accuracy. The reviewed literature indicates that some transducers can introduce errors due to their nonlinearities. The study also identifies the limitations of calibrating these transducers at frequencies above 2 kHz due to the unavailability of suitable sources capable of generating the required test waveforms. Furthermore, the study emphasizes the necessity for establishing accuracy limits for harmonic measurements above 2 kHz.
Keywords: power quality; medium voltage; high voltage; extra high voltage; high-frequency harmonics; instrument voltage transformers; frequency response; high voltage calibration (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/4/892/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/4/892/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:4:p:892-:d:1338890
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().