Power Production, Inter- and Intra-Array Wake Losses from the U.S. East Coast Offshore Wind Energy Lease Areas
Sara C. Pryor () and
Rebecca J. Barthelmie
Additional contact information
Sara C. Pryor: Department of Earth and Atmospheric Sciences, Cornell University, Ithaca, NY 14853, USA
Rebecca J. Barthelmie: Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853, USA
Energies, 2024, vol. 17, issue 5, 1-30
Abstract:
There is an urgent need to develop accurate predictions of power production, wake losses and array–array interactions from multi-GW offshore wind farms in order to enable developments that maximize power benefits, minimize levelized cost of energy and reduce investment uncertainty. New, climatologically representative simulations with the Weather Research and Forecasting (WRF) model are presented and analyzed to address these research needs with a specific focus on offshore wind energy lease areas along the U.S. east coast. These, uniquely detailed, simulations are designed to quantify important sources of wake-loss projection uncertainty. They sample across different wind turbine deployment scenarios and thus span the range of plausible installed capacity densities (ICDs) and also include two wind farm parameterizations (WFPs; Fitch and explicit wake parameterization (EWP)) and consider the precise WRF model release used. System-wide mean capacity factors for ICDs of 3.5 to 6.0 MWkm −2 range from 39 to 45% based on output from Fitch and 50 to 55% from EWP. Wake losses are 27–37% (Fitch) and 11–19% (EWP). The discrepancy in CF and wake losses from the two WFPs derives from two linked effects. First, EWP generates a weaker ‘deep array effect’ within the largest wind farm cluster (area of 3675 km 2 ), though both parameterizations indicate substantial within-array wake losses. If 15 MW wind turbines are deployed at an ICD of 6 MWkm −2 the most heavily waked wind turbines generate an average of only 32–35% of the power of those that experience the freestream (undisturbed) flow. Nevertheless, there is no evidence for saturation of the resource. The wind power density (electrical power generation per unit of surface area) increases with ICD and lies between 2 and 3 Wm −2 . Second, EWP also systematically generates smaller whole wind farm wakes. Sampling across all offshore wind energy lease areas and the range of ICD considered, the whole wind farm wake extent for a velocity deficit of 5% is 1.18 to 1.38 times larger in simulations with Fitch. Over three-quarters of the variability in normalized wake extents is attributable to variations in freestream wind speeds, turbulent kinetic energy and boundary layer depth. These dependencies on meteorological parameters allow for the development of computationally efficient emulators of wake extents from Fitch and EWP.
Keywords: wind turbines; mesoscale model; WRF; wake modeling; array–array interactions; Fitch; EWP; capacity factors; wake extent; ‘deep array effect’ (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/5/1063/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/5/1063/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:5:p:1063-:d:1344684
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().