Research on Insulation Configuration of 220 kV Bushing in High-Altitude Polluted Areas
Zhijin Zhang (),
Yuanpeng Zhang,
Wei Xiao,
Yong Sun and
Xingliang Jiang
Additional contact information
Zhijin Zhang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Yuanpeng Zhang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Wei Xiao: Southern Power Grid Research Institute Co., Ltd., Guangzhou 510663, China
Yong Sun: Electric Power Research Institute of EHV Power Transmission, Company of China Southern Power Grid, Guangzhou 510663, China
Xingliang Jiang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Energies, 2024, vol. 17, issue 7, 1-15
Abstract:
The external insulation strength of the power equipment sleeve in the substation and converter station will be reduced with the increase in altitude and atmosphere pollution. The weakness of external insulation seriously threatens the safe operation of electrical equipment. At present, there are few studies and conclusions that focus on the flashover characteristics of power equipment bushing in high-altitude polluted areas. Therefore, this paper takes the 220 kV voltage level bushing as the research object and studies the Alternating Current (AC) pollution flashover characteristics and lightning and switching impulse flashover characteristics at low pressure. The insulation configuration at high-altitude polluted areas is analyzed. Finally, the insulation configuration scheme, which is suitable for high-altitude polluted areas, is proposed. The results show that the AC pollution flashover voltages of the bushing decrease with the decrease in the atmospheric pressure and the increase in the salt density as a power exponent function. The impulse flashover voltages also decrease with the decrease in the atmospheric pressure as a power exponent function. The atmospheric pressure/pollution impact characteristic index is related to the type of voltage, the value of the atmospheric pressure, and the value of the salt density. The test bushing does not meet the insulation configuration requirements in some high-altitude polluted areas. Through the analysis and calculation of the test results, the bushing insulation configuration scheme in high-altitude polluted areas is proposed. The research results can provide a reference for the external insulation design of bushings in substations and converter stations in high-altitude polluted areas.
Keywords: bushing; AC pollution flashover characteristics; impulse flashover characteristics; high-altitude; insulation configuration (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/7/1645/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/7/1645/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:7:p:1645-:d:1366575
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().