Analysis of Solar Radiation Differences for High-Voltage Transmission Lines on Micro-Terrain Areas
Hualong Zheng (),
Yizhang Wang,
Dexin Xie,
Zhijin Zhang and
Xingliang Jiang
Additional contact information
Hualong Zheng: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Yizhang Wang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Dexin Xie: Chongqing Electric Power Design Institute Co., Ltd., Chongqing 404100, China
Zhijin Zhang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Xingliang Jiang: Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China
Energies, 2024, vol. 17, issue 7, 1-16
Abstract:
The stable operation of high-voltage transmission lines is significantly affected by atmospheric icing. Research on the physical processes of icing and de-icing of transmission lines in micro-terrain, as well as the factors affecting them, is a crucial theoretical foundation for enhancing current icing prediction capabilities and guiding the planning of transmission lines in mountainous areas. The difficulty lies in the fact that, unlike the calculation of surface radiation, the amount of radiation received by the lines is affected by a combination of terrain, environmental shading, and the orientation of the lines. Therefore, this work initially establishes a method for calculating the total amount of radiant heat received per unit length of the line throughout the day at various heights from the ground, based on the angle of solar incidence and the three-dimensional spatial position of the lines. Furthermore, a method of mapping the regional heat radiation by gridding the direction of the lines was proposed, providing the daily heat radiation and equivalent Joule heat. The proposed mapping method supports anti-icing planning for high-voltage transmission lines in micro-terrain areas.
Keywords: high-voltage operation; micro-terrain; transmission lines ice-covers (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/7/1684/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/7/1684/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:7:p:1684-:d:1368639
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().