EconPapers    
Economics at your fingertips  
 

A Control Strategy for Achieving Constant Voltage Output with an Extensive ZVS Operating Range in Bidirectional Wireless EV Charging Systems

Guangyao Li, Yafei Chen, Hailong Zhang, Junchen Xie, Seungjin Jo and Dong-Hee Kim ()
Additional contact information
Guangyao Li: Department of Electrical Engineering, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
Yafei Chen: College of Electrical and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China
Hailong Zhang: Department of Information and Control Engineering, Qingdao University of Technology, Qingdao 266525, China
Junchen Xie: Department of Electrical Engineering, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
Seungjin Jo: Department of Electrical Engineering, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
Dong-Hee Kim: Department of Electrical Engineering, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea

Energies, 2024, vol. 17, issue 8, 1-18

Abstract: Variations in the coupling coefficient of loosely coupled transformers and dynamic loads have a significant impact on the overall performance of bidirectional inductive power transfer (BIPT) systems. However, a wide range of load and coupling coefficient variations are common in the actual charging process, which may cause the converter on both sides to operate in a hard switching state, resulting in switching noise, reduced efficiency, and potential safety concerns. In this paper, a triple-phase-shift control (TPSC) strategy is proposed to study the zero-voltage switching (ZVS) operating range and constant-voltage output (CVO) characteristics of the double-side-LCC (DS-LCC) topology. To ensure a CVO over the wide range of coupling coefficient variations, a dual-phase-shift control is introduced for AC voltage matching. Based on this, the third phase-shift angle control between the converters on both sides is introduced to ensure the ZVS realization. Meanwhile, the time-domain model is developed to analyze the rationality of the proposed third phase-shift angle and the ZVS operating range. Finally, the effectiveness of the proposed TPSC strategy is validated through a 1.5 kW experimental prototype with an air gap of 100–150 mm.

Keywords: bidirectional inductive power transfer (BIPT); triple-phase-shift control (TPSC); constant-voltage output (CVO); battery charging; zero-voltage switching (ZVS) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/17/8/1819/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/8/1819/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:8:p:1819-:d:1373303

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:17:y:2024:i:8:p:1819-:d:1373303