Design and Experimental Tests of a Four-Way Valve with the Determination of Flow Characteristics for Building Central Heating Installations Using Solid Modeling
Mariusz Niekurzak () and
Jerzy Mikulik
Additional contact information
Mariusz Niekurzak: Faculty of Management, AGH University of Krakow, 30-067 Krakow, Poland
Jerzy Mikulik: Faculty of Management, AGH University of Krakow, 30-067 Krakow, Poland
Energies, 2024, vol. 17, issue 9, 1-27
Abstract:
The article presents the design of a four-way valve, implemented in SolidWorks software (SOLIDWORKS ® i 3DEXPERIENCE ® Works Simulation) and used for central heating installations in buildings. The project was carried out in order to examine the innovative design of the medium mixing mechanism and to conduct strength and FMEA analysis. The innovative solutions proposed by the authors in this work will allow valves of this type to meet stringent environmental standards. These standards are currently being introduced for this type of structural element of machine parts as part of the energy transformation of buildings. Potential failures occurring in individual elements of the four-way valve were also tested using Failure mode and effects analysis. In addition, strength tests were performed in SolidWorks software using static analysis, and optimization tests were performed on the refrigerant in terms of its impact on the environment. The characteristics of the tested materials in the valve design show that the best materials are brass and stainless steel. Brass has a Poisson’s ratio of 0.33, a tensile strength of 478.4 MPa and a yield strength of 239.7 MPa. In turn, stainless steel is characterized by the following parameters: Poisson’s ratio of 0.27, tensile strength of 685 MPa and yield strength of 292 MPa. The designed valve reduces energy consumption by 30% through a properly designed medium flow with the appropriate selection of materials. Moreover, the design reduces the thickness of the contaminant layer by 0.17 mm, with a capacity factor of −2.50% and an evaporator Δ p of 3.10% (53 kPa). The performed research provides knowledge on the subject selection of appropriate material, a description of the potential failures of the structural elements of the designed four-way valve and methods of counteracting these failures. The article presents the optimization role of the tested component in the context of sustainable development.
Keywords: four-way valve; mixing valve; heating; cooling; optimization of working medium flow; sustainable development; assembly design in SolidWorks software (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/17/9/2152/pdf (application/pdf)
https://www.mdpi.com/1996-1073/17/9/2152/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:17:y:2024:i:9:p:2152-:d:1386968
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().