Experimental Testing of a Heat Exchanger with Composite Material for Deep Dehumidification
Valeria Palomba (),
Antonio Fotia,
Fabio Costa,
Davide La Rosa and
Vincenza Brancato
Additional contact information
Valeria Palomba: National Research Council of Italy, Institute for Advanced Energy Technologies “N. Giordano” (CNR-ITAE), Salita S, Lucia sopra Contesse 5, 98126 Messina, Italy
Antonio Fotia: National Research Council of Italy, Institute for Advanced Energy Technologies “N. Giordano” (CNR-ITAE), Salita S, Lucia sopra Contesse 5, 98126 Messina, Italy
Fabio Costa: National Research Council of Italy, Institute for Advanced Energy Technologies “N. Giordano” (CNR-ITAE), Salita S, Lucia sopra Contesse 5, 98126 Messina, Italy
Davide La Rosa: National Research Council of Italy, Institute for Advanced Energy Technologies “N. Giordano” (CNR-ITAE), Salita S, Lucia sopra Contesse 5, 98126 Messina, Italy
Vincenza Brancato: National Research Council of Italy, Institute for Advanced Energy Technologies “N. Giordano” (CNR-ITAE), Salita S, Lucia sopra Contesse 5, 98126 Messina, Italy
Energies, 2025, vol. 18, issue 10, 1-21
Abstract:
Deep dehumidification is crucial for industrial applications requiring ultra-low humidity levels. Traditional cooling-based dehumidification struggles to achieve low dew points efficiently due to excessive energy consumption and frost formation risks. As an alternative, desiccant-based methods, particularly solid desiccant systems, offer improved performance with lower energy demands. This study experimentally investigates a fixed-bed dehumidification system utilizing a plate-fin heat exchanger filled with a silica gel/calcium chloride composite material. The performance evaluation focuses on the influence of ambient conditions and operating parameters, including air velocity and cooling fluid temperature. Among these, the most influential parameter was the velocity of air. For the tested heat exchanger, an optimum value in the range of 0.4–0.6 m/s was identified. Under optimal conditions, the tested HEX was able to reduce the dew point of air down to −2 °C, achieving a reduction in the humidity ratio up to 13 g/kg. The results indicate that air velocity significantly impacts also heat and mass transfer, with coefficients ranging from 80 to 140 W/(m 2 K) and 0.015 to 0.060 kg/(m 2 s), respectively. The findings highlight the potential of composite desiccant fixed-bed systems for efficient deep dehumidification, outperforming conventional lab-scale components in heat and mass transfer effectiveness. A comparison with other works in the literature indicated that up to 30% increased mass transfer coefficient was achieved and up to seven times higher heat transfer coefficient was measured.
Keywords: adsorption; deep dehumidification; calcium chloride-based composite (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/10/2418/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/10/2418/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:10:p:2418-:d:1651612
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().