EconPapers    
Economics at your fingertips  
 

Numerical Simulation of a 330 MW Tangentially Fired Boiler by a Model Coupling CFD and Hydrodynamic Calculation

Lijun Sun, Miao Wang, Peian Chong, Yunhao Shao and Lei Deng ()
Additional contact information
Lijun Sun: Huayuan Power Plant, State Grid Energy Hami Coal and Power Co., Ltd., Hami 839000, China
Miao Wang: Huayuan Power Plant, State Grid Energy Hami Coal and Power Co., Ltd., Hami 839000, China
Peian Chong: Shanghai Power Equipment Research Institute Co., Ltd., Shanghai 200240, China
Yunhao Shao: State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Lei Deng: State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China

Energies, 2025, vol. 18, issue 10, 1-19

Abstract: The interaction mechanism of multi-physical fields in a 330 MW tangentially fired boiler is explored by coupling the CFD (computational fluid dynamics) model and the working fluid side hydrodynamic model under steady-state conditions. The research focuses on the flue gas flow field, the hydrodynamic safety of the water wall, the variation of the working fluid parameters and the formation and distribution characteristics of sulfide (SO 2 , H 2 S) under different steady loads (35%, 50%, 75%, 100% Boiler Maximum Continuous Rating). The results show that under high load, the flue gas attaches to the wall. The overall stagnation differential pressure ratio (1.85–2.07) and reversal differential pressure ratio (1.22–1.30) of the G1 tube group with the lowest heat flux are higher than the safety threshold (1.05), proving reliable operational safety under equilibrium conditions. The temperature distribution of the furnace center obtained by numerical simulation is consistent with the actual situation. The mass fraction of sulfide increases significantly with the increase in load. SO 2 is mainly distributed in the wall area of the middle and upper burners, while H 2 S is mainly distributed in the wall area between the secondary air and the main burner. The maximum mass fractions of SO 2 and H 2 S at 330 MW are 0.120% and 0.0524%, respectively. It is suggested that a wall-attached air system be added to inhibit the enrichment of corrosive gases. This work may provide theoretical support and engineering guidance for multi-objective optimization design and high temperature corrosion prevention and control of tangentially fired boilers.

Keywords: tangentially fired boiler; CFD; hydrodynamic calculation; flue gas flow field; stability of hydro-power; high temperature corrosion (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/10/2585/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/10/2585/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:10:p:2585-:d:1657566

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-06-07
Handle: RePEc:gam:jeners:v:18:y:2025:i:10:p:2585-:d:1657566