Study on the Influence of Grounding Resistance on Cable Fault Overvoltage

Baotong Song, Sihan Wang, Changyuan Xiang, Xiaoyue Chen () and Ju Tang
Additional contact information
Baotong Song: Beijing Electric Power Economic and Technical Research Institute Co., Ltd., Beijing 100055, China
Sihan Wang: Beijing Electric Power Economic and Technical Research Institute Co., Ltd., Beijing 100055, China
Changyuan Xiang: Beijing Electric Power Economic and Technical Research Institute Co., Ltd., Beijing 100055, China
Xiaoyue Chen: School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
Ju Tang: School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China

Energies, 2025, vol. 18, issue 10, 1-14

Abstract: The cable grounding connecting method and grounding resistance have a significant influence on the cable fault overvoltage. This paper considers a 500 kV long cable project in Beijing as the research object; a model was implemented in ATP-EMTP, and simulation results show how grounding resistance and its connection method influence the cable fault overvoltage. When the grounding resistances are all set to the same value along the cable, as the grounding resistance increases, the frequency of overvoltage at the cable fault point also increases. When all grounding resistances along the cable are set to same value, if a connection method considering conduction impedance is adopted, the fault point frequency overvoltage also increases. If the grounding resistance at both ends of the cable are connected to the substation, the sequence impedance of the cable will decrease, resulting in a reduction in the fault point overvoltage. Additionally, this paper analyzes the influence of grounding material on the cable line sequence impedance. When the grounding resistance value is set to 5 Ω according to the national standard, the cable line fault overvoltage under single-phase grounding fault with load reduction is simulated and analyzed, and it is found that connecting the grounding devices at both ends of the cable to the substation can effectively suppress the overvoltage along the cable.

Keywords: power cable; grounding resistance; asymmetric ground fault; power frequency overvoltage (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/10/2601/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/10/2601/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:10:p:2601-:d:1658209

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-06-07
Handle: RePEc:gam:jeners:v:18:y:2025:i:10:p:2601-:d:1658209