A Modeling Study on the Impact of Coal Power in Wind–Solar–Thermal Storage System
Yuhua Liu,
Qinggang Lyu (),
Zhengnan Gao,
Shujun Zhu,
Jinming Fu,
Yongjiang Liu,
Ming Gao and
Zhen Chai
Additional contact information
Yuhua Liu: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Qinggang Lyu: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Zhengnan Gao: Inner Mongolia Power (Group) Co., Ltd., Hohhot 010010, China
Shujun Zhu: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Jinming Fu: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Yongjiang Liu: Inner Mongolia Power (Group) Co., Ltd., Hohhot 010010, China
Ming Gao: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Zhen Chai: State Key Laboratory of Coal Conversion, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Energies, 2025, vol. 18, issue 11, 1-17
Abstract:
To further quantify the role of coal-fired power units in a wind–solar–thermal storage system and improve the construction of clean energy bases, this study examined the temporal production characteristics of wind and solar power and established an operational model for coal-fired power units within a wind–solar–thermal storage system. This approach ensured a stable electricity supply on the basis of power balance. The findings indicate that the correlation between the installed capacity of coal-fired power and the daily power supply capability of energy storage that meets various scheduled power demands can be obtained via the model. As the proportion of wind and solar power in the output power decreases, the influence of the minimum operational load of the coal-fired power units on the curtailment rate intensifies. Notably, the operational cost savings from reducing this minimum operational load surpass those obtained by either downsizing the installed capacity of coal-fired power units or energy storage devices. Among the parameters of this study, the lowest operational cost for the system was observed when wind and solar power generation constituted 76% of the total. This scenario, which ensured stable power output for 95% of the days in a year, had a wind and solar power curtailment rate of 11.3%. Additionally, the energy supplied by storage devices amounted to 1000 MWh, with the ratio of the installed capacity of coal-fired power to the total installed capacities of wind and solar power remaining at 25%. When the ratio of wind and solar power generation to output power was 91%, 76%, and 58%, a 1% reduction in coal consumption by coal-fired units during low-load operation resulted in a decrease in total system operating costs of 0.012%, 0.093%, and 0.089%, respectively. These findings provide valuable data support for the development of clean energy infrastructures.
Keywords: power balance; wind–solar–thermal storage system; coal-fired power; flexibility; sequential production (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/11/2819/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/11/2819/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:11:p:2819-:d:1666855
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().