EconPapers    
Economics at your fingertips  
 

The Impact of Terminal-Voltage Control on the Equilibrium Points and Small-Signal Stability of GFL-VSC Systems

Shun Li, Xing Yao, Cong Fu, Meng Zhan () and Bo Bao
Additional contact information
Shun Li: Power Dispatching Control Center of Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
Xing Yao: School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Cong Fu: Power Dispatching Control Center of Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
Meng Zhan: School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Bo Bao: Power Dispatching Control Center of Guangdong Power Grid Co., Ltd., Guangzhou 510000, China

Energies, 2025, vol. 18, issue 12, 1-21

Abstract: Weak grid stability is crucial for grid-following voltage source converter (GFL-VSC) systems. Current studies primarily focus on the interaction analyses between active-power loops, whereas the influence of reactive-power loops remains unclear. To address this problem, this study focuses on terminal-voltage control (TVC) and analyzes its impact on equilibrium points (EPs) and small-signal stability by varying the TVC response speed, including three different cases: considering TVC dynamics, considering TVC rapid responses, and considering TVC slow responses. Firstly, the models of the GFL-VSC system under different scenarios are established and compared. In the EP analysis, for both TVC dynamics and TVC rapid responses, the EP of an active current remains constant and it becomes unstable in a weak grid, whereas for TVC slow responses, the EP undergoes trans-critical bifurcation; specifically, the other EP becomes stable after this bifurcation. Further, in the small-signal stability analysis, three equivalent Heffron–Phillips models based on the phase-locked loop synchronization dynamics with additional synchronization and damping coefficients are constructed and studied. By these systematical studies, the impacts of different TVC response speeds are clarified and summarized, and these analytical results are well supported by MATLAB/Simulink simulations and hardware-in-the-loop experiments.

Keywords: renewable energy integration; grid-following converter; terminal-voltage control; small-signal stability; response speed; complex torque method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/12/3023/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/12/3023/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:12:p:3023-:d:1673607

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-06-07
Handle: RePEc:gam:jeners:v:18:y:2025:i:12:p:3023-:d:1673607