Improving the Flexibility of Coal-Fired Power Units by Dynamic Cold-End Optimization
Yanpeng Zhang,
Xinzhen Fang,
Zihan Kong,
Zijiang Yang,
Jinxu Lao,
Wei Zheng,
Lingkai Zhu and
Jiwei Song ()
Additional contact information
Yanpeng Zhang: Shandong Zhongshi Yitong Group Co., Ltd., 2010 Wangyue Road, Jinan 250002, China
Xinzhen Fang: Shandong Zhengyuan Industrial Development Co., Ltd., 150 Jing’er Road, Jinan 250000, China
Zihan Kong: Shandong Wangrui Materials Co., Ltd., No. 17 Jingsan Road, Jinan 250000, China
Zijiang Yang: Shandong Zhengyuan Industrial Development Co., Ltd., 150 Jing’er Road, Jinan 250000, China
Jinxu Lao: Shandong Zhongshi Yitong Group Co., Ltd., 2010 Wangyue Road, Jinan 250002, China
Wei Zheng: State Grid Shandong Electric Power Research Institute, 2000 Wangyue Road, Jinan 250003, China
Lingkai Zhu: State Grid Shandong Electric Power Research Institute, 2000 Wangyue Road, Jinan 250003, China
Jiwei Song: Institute of Thermal Science and Technology, Shandong University, Jinan 250061, China
Energies, 2025, vol. 18, issue 13, 1-21
Abstract:
Traditional coal-fired power units are required to improve their operational flexibility to accommodate increasing renewable energy. In this paper, an optimized operation approach of the cold-end system is proposed to improve the flexibility of coal-fired power units. The dynamic models of the cold-end system of a 330 MW coal-fired power unit are developed. The model validation results show that the error between the simulated results and measured values is <3% at the common load range and <5% at the low load range. The applications of cold-end optimization in the load-variation processes with ±3% Pe/min ramps and actual automatic generation control (AGC) response are then studied. The results show that when the back pressure of the unit is relatively low, the cold-end optimization is more effective in improving the ramp-down rate. On the contrary, when the unit operates with relatively high back pressure, this approach is more suitable for improving the ramp-up rate. Moreover, the AGC response quality is noticeably enhanced, which improves the phenomenon of overshooting and reverse regulation. The comprehensive performance indicator K P increased from 2.27 to 4.63 in the summer scenario, while it increased from 2.08 to 4.34 in the winter scenario. Moreover, the profits under the two scenarios are raised by 39.2% and 42.5%, respectively. The findings of this study are also applicable to supercritical units or other power units with the cold end adopting similar water cooling systems. Future work will incorporate advanced control theories to enhance control robustness, which is critical for the practical implementation of the proposed cold-end optimization approach.
Keywords: coal-fired power unit; flexibility; cold-end optimization; dynamic modeling (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/13/3375/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/13/3375/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:13:p:3375-:d:1688746
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().