Abstract:
Accurate diagnosis of the insulation condition of stator windings in pumped storage generator-motor units is crucial for ensuring the safe and stable operation of power systems. Time domain dielectric response testing is an effective method for rapidly diagnosing the insulation condition of capacitive devices, such as those in pumped storage generator-motors. To precisely identify the conductivity and relaxation process parameters of the insulating medium and accurately diagnose the insulation condition of the stator windings, this paper proposes a method for identifying the insulation dielectric response parameters of stator windings based on sparsity-enhanced dynamic mode decomposition of the depolarization current. First, the measured depolarization current time series is processed through dynamic mode decomposition (DMD). An iterative reweighted L1 (IRL1)-based method is proposed to formulate a reconstruction error minimization problem, which is solved using the ADMM algorithm. Based on the computed modal amplitudes, the dominant modes—representing the main insulation relaxation characteristics—are separated from spurious modes caused by noise. The parameters of the extended Debye model (EDM) are then calculated from the dominant modes, enabling precise identification of the relaxation characteristic parameters. Finally, the accuracy and feasibility of the proposed method are verified through a combination of simulation experiments and laboratory tests.
Keywords: polarization/depolarization current method; dynamic mode decomposition; ADMM algorithm; extended Debye model; pumped storage generator-motor; winding insulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/13/3382/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/13/3382/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:13:p:3382-:d:1688893
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().