Research on the Heavy Gas Setting Method of Oil-Immersed Transformer Based on Oil Flow Acceleration Characteristics

Yuangang Sun, Zhixiang Tong, Jian Mao, Junchao Wang, Shixian He, Tengbo Zhang and Shuting Wan ()
Additional contact information
Yuangang Sun: Wudongde Hydropower Plant, China Yangtze Power Co., Ltd., Kunming 650214, China
Zhixiang Tong: Wudongde Hydropower Plant, China Yangtze Power Co., Ltd., Kunming 650214, China
Jian Mao: Wudongde Hydropower Plant, China Yangtze Power Co., Ltd., Kunming 650214, China
Junchao Wang: Wudongde Hydropower Plant, China Yangtze Power Co., Ltd., Kunming 650214, China
Shixian He: Hebei Key Laboratory of Health Maintenance and Failure Prevention of Electric Machinery and Equipment, North China Electric Power University, Baoding 071003, China
Tengbo Zhang: Hebei Key Laboratory of Health Maintenance and Failure Prevention of Electric Machinery and Equipment, North China Electric Power University, Baoding 071003, China
Shuting Wan: Hebei Key Laboratory of Health Maintenance and Failure Prevention of Electric Machinery and Equipment, North China Electric Power University, Baoding 071003, China

Energies, 2025, vol. 18, issue 14, 1-20

Abstract: As the key non-electric protection equipment of an oil-immersed transformer, the gas relay plays an important role in ensuring the safe operation of the transformer. To further enhance the sensitivity of gas relays for the heavy gas alarm, this paper takes the BF type double float gas relay as the research object and proposes a new method for heavy gas setting, which is based on the internal oil flow acceleration characteristics of the gas relay. Firstly, the analytical derivation of the force acting on the gas relay baffle is carried out, and through theoretical analysis, the internal mechanism of heavy gas action under transient oil flow excitation is revealed. Then, the numerical simulation and experimental research on the variation of oil flow velocity and acceleration under different fault energies are carried out. The results show that with the increase of fault energy, the oil flow velocity fluctuates up and down during heavy gas action, but the oil flow acceleration shows a linear correlation. The oil flow acceleration can be set as the threshold of heavy gas action, and the severity of the fault can be judged. At the same time, the alarm time of the heavy gas setting method based on the oil flow acceleration characteristics is greatly shortened, which can reflect the internal fault of the transformer in time and significantly improve the sensitivity of the heavy gas alarm.

Keywords: oil-immersed transformer; gas relay; heavy gas setting; oil flow acceleration; oil flow velocity (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/14/3859/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/14/3859/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:14:p:3859-:d:1705785

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-07-24
Handle: RePEc:gam:jeners:v:18:y:2025:i:14:p:3859-:d:1705785