Impact of Bedroom Ventilation Strategy on Air Change Rates and Indoor Air Parameters in the Autumn–Winter Seasons—In Situ Study in Poland

Maria Kostka (), Zuzanna Kołodko and Magdalena Baborska-Narożny ()
Additional contact information
Maria Kostka: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, ul. Norwida 4/6, 50-373 Wroclaw, Poland
Zuzanna Kołodko: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, ul. Norwida 4/6, 50-373 Wroclaw, Poland
Magdalena Baborska-Narożny: Faculty of Architecture, Wroclaw University of Science and Technology, ul. Bolesława Prusa 53/55, 50-317 Wroclaw, Poland

Energies, 2025, vol. 18, issue 16, 1-27

Abstract: Hybrid ventilation is indicated as one of the effective methods of maintaining thermal comfort and indoor air quality and reducing energy consumption in buildings. It assumes the capacity to switch between natural and mechanical ventilation, allowing the most efficient use of the outdoor air potential. This article aims to quantify the impact of changing ventilation system, from natural to hybrid, on indoor air parameters and air change rates in a bedroom of a single-family house. The distinct aspects of this study include longitudinal measurement over three years, natural ventilation substituted by hybrid ventilation halfway into the monitoring period, and unaltered building and user characteristics. The analysis is based on measurements of temperature, relative humidity, CO2 concentration, and window opening for three seven-month measurement periods from September 1 to March 31. The measurements are complemented by in-depth user feedback and an audit of the building structure and installed HVAC systems. A clear correlation was observed between the values of relative humidity and carbon dioxide concentration and the type of ventilation strategy. A significant influence of residents’ behavior on the achieved indoor air parameters was observed.

Keywords: hybrid ventilation; MVHR; natural ventilation; indoor air quality; bedroom ventilation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/16/4279/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/16/4279/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:16:p:4279-:d:1722317

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-08-12
Handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4279-:d:1722317