EconPapers    
Economics at your fingertips  
 

Experimental Assessment of a Passive Waste Heat Recovery System Using Thermosyphons and Thermoelectric Generators for Integration into District Heating Applications

Luis V. G. Fachini, Pedro Leineker Ochoski Machado, Kamal A. R. Ismail, Felipe M. Biglia, Aleffe J. C. Vaz, Romeu M. Szmoski and Thiago Antonini Alves ()
Additional contact information
Luis V. G. Fachini: Graduate Program in Mechanical Engineering, Federal University of Technology-Parana (UTFPR), Ponta Grossa 84017-220, PR, Brazil
Pedro Leineker Ochoski Machado: Graduate Program in Mechanical and Materials Engineering, Federal University of Technology-Parana (UTFPR), Curitiba 81280-340, PR, Brazil
Kamal A. R. Ismail: Energy Department, Faculty of Mechanical Engineering, State University of Campinas, Mendeleiev St., 200, University City, Campinas 13083-860, SP, Brazil
Felipe M. Biglia: Graduate Program in Mechanical and Materials Engineering, Federal University of Technology-Parana (UTFPR), Curitiba 81280-340, PR, Brazil
Aleffe J. C. Vaz: Graduate Program in Mechanical Engineering, Federal University of Technology-Parana (UTFPR), Ponta Grossa 84017-220, PR, Brazil
Romeu M. Szmoski: Physics Department, Federal University of Technology-Parana (UTFPR), Ponta Grossa 84017-220, PR, Brazil
Thiago Antonini Alves: Graduate Program in Mechanical Engineering, Federal University of Technology-Parana (UTFPR), Ponta Grossa 84017-220, PR, Brazil

Energies, 2025, vol. 18, issue 19, 1-33

Abstract: The efficient recovery of waste heat is essential for improving sustainability in industrial and urban energy systems. This study presents the experimental evaluation of a passive heat recovery unit composed of finned thermosyphons and Bismuth Telluride (Bi 2 Te 3 ) thermoelectric generators (TEGs). The primary objective was to characterize its simultaneous thermal recovery and electrical generation capabilities under airflow and temperature conditions simulating low-grade industrial exhaust streams. The system was tested in an open-loop wind tunnel simulating exhaust gases under air velocities of 0.6, 1.1, and 1.7 m/s. Heat was transferred to the TEGs through finned thermosyphons, enabling power generation via the Seebeck effect. The passive heat exchange mechanism successfully recovered up to 250.9 W of thermal power, preheating the inlet air by a maximum of 9.5 °C with a peak thermal effectiveness of 44.4%. Simultaneously, the system achieved a maximum temperature difference of 30.0 °C across the thermoelectric modules, generating a total electrical power of 163.7 mW (81.8 mW per TEG). This dual-purpose operation resulted in a maximum overall first-law efficiency of 9.38% and an electrical power density of 52.20 W/m 2 from the low-grade thermal stream. These results confirm the technical feasibility of this compact, passive, and maintenance-free design, highlighting its potential for integration into applications like district heating or industrial ventilation, where balancing thermal and electrical outputs is crucial.

Keywords: district heating; heat recovery; Seebeck effect; thermoelectic generator; thermosyphon; waste heat (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/19/5090/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/19/5090/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:19:p:5090-:d:1757625

Access Statistics for this article

Energies is currently edited by Ms. Cassie Shen

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-09-26
Handle: RePEc:gam:jeners:v:18:y:2025:i:19:p:5090-:d:1757625